In this paper the development and realization of a compact measurement system for ballisto-cardiogram recording is reported. The system is based on a Linkit ONE, an ARDUINO-like embedded system, and an electronic interface specifically designed as a 'Shield' configuration to reduce the dimensions of the entire system. Measurement is electrodeless. Respiration and heartbeat frequency is acquired in the seated position, using a quasi-piezoelectric sensor, made of an electroactive polymer material (EMFIT). The sensing material is in the shape of a small flat oval placed directly on the chair and connected with the measurement system. Preliminary results are reported and discussed.

A ballistocardiogram acquisition system for respiration and heart rate monitoring / Hermann, Sonja; Lombardo, Luca; Campobello, Giuseppe; Burke, Martin; Donato, Nicola. - ELETTRONICO. - 1:(2018), pp. 1-5. (Intervento presentato al convegno 2018 IEEE International Instrumentation and Measurement Technology Conference, I2MTC 2018 tenutosi a Royal Sonesta Hotel, usa nel 2018) [10.1109/I2MTC.2018.8409750].

A ballistocardiogram acquisition system for respiration and heart rate monitoring

LOMBARDO, LUCA;
2018

Abstract

In this paper the development and realization of a compact measurement system for ballisto-cardiogram recording is reported. The system is based on a Linkit ONE, an ARDUINO-like embedded system, and an electronic interface specifically designed as a 'Shield' configuration to reduce the dimensions of the entire system. Measurement is electrodeless. Respiration and heartbeat frequency is acquired in the seated position, using a quasi-piezoelectric sensor, made of an electroactive polymer material (EMFIT). The sensing material is in the shape of a small flat oval placed directly on the chair and connected with the measurement system. Preliminary results are reported and discussed.
2018
9781538622223
File in questo prodotto:
File Dimensione Formato  
IMTC2018_Lombardo_08409750.pdf

non disponibili

Descrizione: articolo principale
Tipologia: 2a Post-print versione editoriale / Version of Record
Licenza: Non Pubblico - Accesso privato/ristretto
Dimensione 3.38 MB
Formato Adobe PDF
3.38 MB Adobe PDF   Visualizza/Apri   Richiedi una copia
2018 - A ballistocardiogram acquisition system for respiratory and heart rate monitoring, I2MTC 2018 [AC-PID5220119].pdf

accesso aperto

Descrizione: Author copy
Tipologia: 2. Post-print / Author's Accepted Manuscript
Licenza: PUBBLICO - Tutti i diritti riservati
Dimensione 2.28 MB
Formato Adobe PDF
2.28 MB Adobe PDF Visualizza/Apri
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11583/2712115