The high seismic vulnerability of precast industrial facilities is often due to the loss of the support by the beams due to the overcoming of frictional resistance of joints. In order to inhibit sliding, retrofit interventions proposed provide using steel connections of beam-column joints. These, while effectively avoiding sliding, can lead, to an increase of seismic demand for the structure due to the modification of the static scheme. In this paper the dynamic response of systems representative of the mechanical behaviour of prefabricated industrial facilities with and without mechanical joint connections is analysed. These are considered as inelastic single degree of freedom systems. Following an extensive parametric analysis, performed using 30 compatible spectrum accelerograms, inelastic demand spectra are defined for relative beam / column displacements and displacements at the head of the column. The latter can be used for the verification of precast industrial facilities with and without mechanical joint connections./ L'elevata vulnerabilità sismica delle strutture industriali prefabbricate è spesso dovuta alla perdita dell’appoggio da parte delle travi per via del superamento della resistenza attritiva del giunto. Per inibire tale scorrimento, sono stati proposti interventi che prevedono l’impiego di connessioni metalliche dei nodi trave-colonna. Questi, pur riuscendo efficacemente ad evitare lo scorrimento trave/colonna, possono comportare, in ragione della modifica dello schema statico, un aggravio della domanda sismica per la costruzione. Nel presente lavoro viene analizzata la risposta dinamica di sistemi rappresentativi del comportamento meccanico di capannoni industriali prefabbricati con e senza unioni meccaniche tra travi e colonne considerati come sistemi inelastici ad un grado di liberta. A valle di un’estesa analisi parametrica svolta mediante l’impiego di 30 accelerogrammi spettro compatibili, vengono definiti gli spettri di domanda inelastica di spostamento relativo trave/colonna e spostamento in testa alla colonna, da impiegare per la verifica di sistemi con e senza unioni meccaniche nei giunti.

Inelastic displacement spectra for seismic verification of industrial facilities / Spettri di spostamento inelastici per la verifica sismica di capannoni industriali / DI TRAPANI, Fabio; Ferro, GIUSEPPE ANDREA; Restuccia, Luciana. - ELETTRONICO. - ITALIAN CONCRETE DAYS - Giornate aicap 2018 Congresso CTE - IL CALCESTRUZZO STRUTTURALE OGGI - TEORIA - IMPIEGHI - MATERIALI – TECNICHE:(2018), pp. 1-8. (Intervento presentato al convegno ITALIAN CONCRETE DAYS - Giornate aicap 2018 Congresso CTE - IL CALCESTRUZZO STRUTTURALE OGGI - TEORIA - IMPIEGHI - MATERIALI – TECNICHE tenutosi a Lecco nel 16-18 Giugno).

Inelastic displacement spectra for seismic verification of industrial facilities / Spettri di spostamento inelastici per la verifica sismica di capannoni industriali

Fabio Di Trapani;Giuseppe Andrea Ferro;Luciana Restuccia
2018

Abstract

The high seismic vulnerability of precast industrial facilities is often due to the loss of the support by the beams due to the overcoming of frictional resistance of joints. In order to inhibit sliding, retrofit interventions proposed provide using steel connections of beam-column joints. These, while effectively avoiding sliding, can lead, to an increase of seismic demand for the structure due to the modification of the static scheme. In this paper the dynamic response of systems representative of the mechanical behaviour of prefabricated industrial facilities with and without mechanical joint connections is analysed. These are considered as inelastic single degree of freedom systems. Following an extensive parametric analysis, performed using 30 compatible spectrum accelerograms, inelastic demand spectra are defined for relative beam / column displacements and displacements at the head of the column. The latter can be used for the verification of precast industrial facilities with and without mechanical joint connections./ L'elevata vulnerabilità sismica delle strutture industriali prefabbricate è spesso dovuta alla perdita dell’appoggio da parte delle travi per via del superamento della resistenza attritiva del giunto. Per inibire tale scorrimento, sono stati proposti interventi che prevedono l’impiego di connessioni metalliche dei nodi trave-colonna. Questi, pur riuscendo efficacemente ad evitare lo scorrimento trave/colonna, possono comportare, in ragione della modifica dello schema statico, un aggravio della domanda sismica per la costruzione. Nel presente lavoro viene analizzata la risposta dinamica di sistemi rappresentativi del comportamento meccanico di capannoni industriali prefabbricati con e senza unioni meccaniche tra travi e colonne considerati come sistemi inelastici ad un grado di liberta. A valle di un’estesa analisi parametrica svolta mediante l’impiego di 30 accelerogrammi spettro compatibili, vengono definiti gli spettri di domanda inelastica di spostamento relativo trave/colonna e spostamento in testa alla colonna, da impiegare per la verifica di sistemi con e senza unioni meccaniche nei giunti.
2018
978-88-99916-11-4
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11583/2711100
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo