This paper is focused on the operation analysis of transformer-based ac drive system with three modulated converters connected specifically to windings of power transformer. It provides multilevel voltage to induction machine by means of three sets of converter-side windings of power transformer. A special switching scheme has been disseminated for adjustment of converters, insuring synchronization of its output voltages and symmetry of voltage waveforms. The total harmonics distortion factor and weighted total harmonic distortion factor have been determined and compared for the basic voltages of this installation. The system performance with three techniques of continuous and discontinuous pulsewidth modulation (PWM) has been evaluated with accent on comparative study of voltage distortion on the converter-side windings of the transformer.

Synchronous undermodulation control modes of system with three PWM converters / Oleschuk, Valentin; Griva, Giovanni Battista; Deriszadeh, Adel; Burcenco, Victoria. - ELETTRONICO. - (2017), pp. 478-482. (Intervento presentato al convegno International Conference on Electromechanical and Power Systems (SIELMEN), 2017 tenutosi a English nel 11-13 Oct. 2017) [10.1109/SIELMEN.2017.8123375].

Synchronous undermodulation control modes of system with three PWM converters

Giovanni Griva;Adel Deriszadeh;
2017

Abstract

This paper is focused on the operation analysis of transformer-based ac drive system with three modulated converters connected specifically to windings of power transformer. It provides multilevel voltage to induction machine by means of three sets of converter-side windings of power transformer. A special switching scheme has been disseminated for adjustment of converters, insuring synchronization of its output voltages and symmetry of voltage waveforms. The total harmonics distortion factor and weighted total harmonic distortion factor have been determined and compared for the basic voltages of this installation. The system performance with three techniques of continuous and discontinuous pulsewidth modulation (PWM) has been evaluated with accent on comparative study of voltage distortion on the converter-side windings of the transformer.
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11583/2698580
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo