Current international standards dealing with efficiency test for filters and filter media focus on measurement of the minimum efficiency at the most penetrating particle size. The available knowledge and instruments provide a solid base for development of test methods to determine the effectiveness of filtration media against airborne nanoparticles down to single-digit nanometer range. An interlaboratory evaluation was performed in the framework of the European Mandate M/461 activities, within the Technical Committee 195 of European Committee for Standardization (CEN/TC195). The purpose was to develop a methodology to determine effectiveness of filtration media against air-borne particles in the 3 – 500 nm range. Five different laboratories (Camfil, ETH/Empa, Politecnico di Torino, University of Minnesota, Unifil) participate in the round robin test in order to verify the repeatability and reproducibility of the test method. The qualification of test rig and apparatus was performed prior of the filtration efficiency and air flow resistance measurement tests.Twilled dutch weave wire mesh was chosen to perform the validation filtration efficiency tests so as to ensure high uniformity of the samples being tested by each different laboratory. We present the experimental data with the discussion about their validity.

Interlaboratory comparison to evaluate the methodology for determination of the media filtration efficiency against nanoparticles / Sachinidou, P.; Chen, S. C.; Pui, D. Y. H.; Tronville, PAOLO MARIA; Mosimann, T.; Eriksson, M.; Wang, J.. - ELETTRONICO. - (2016), pp. 129-129. (Intervento presentato al convegno WFC 12 - 12th World Filtration Congress tenutosi a Taipei nel 11-15 April 2016).

Interlaboratory comparison to evaluate the methodology for determination of the media filtration efficiency against nanoparticles

TRONVILLE, PAOLO MARIA;
2016

Abstract

Current international standards dealing with efficiency test for filters and filter media focus on measurement of the minimum efficiency at the most penetrating particle size. The available knowledge and instruments provide a solid base for development of test methods to determine the effectiveness of filtration media against airborne nanoparticles down to single-digit nanometer range. An interlaboratory evaluation was performed in the framework of the European Mandate M/461 activities, within the Technical Committee 195 of European Committee for Standardization (CEN/TC195). The purpose was to develop a methodology to determine effectiveness of filtration media against air-borne particles in the 3 – 500 nm range. Five different laboratories (Camfil, ETH/Empa, Politecnico di Torino, University of Minnesota, Unifil) participate in the round robin test in order to verify the repeatability and reproducibility of the test method. The qualification of test rig and apparatus was performed prior of the filtration efficiency and air flow resistance measurement tests.Twilled dutch weave wire mesh was chosen to perform the validation filtration efficiency tests so as to ensure high uniformity of the samples being tested by each different laboratory. We present the experimental data with the discussion about their validity.
File in questo prodotto:
File Dimensione Formato  
WFC 12 Scientific Program.pdf

accesso aperto

Descrizione: Programma scientifico del congresso
Tipologia: Altro materiale allegato
Licenza: PUBBLICO - Tutti i diritti riservati
Dimensione 6.48 MB
Formato Adobe PDF
6.48 MB Adobe PDF Visualizza/Apri
G12-2_InterlaboratoryTest.pdf

accesso aperto

Descrizione: Abstract pubblicato negli atti digitali del congresso
Tipologia: Abstract
Licenza: PUBBLICO - Tutti i diritti riservati
Dimensione 83.19 kB
Formato Adobe PDF
83.19 kB Adobe PDF Visualizza/Apri
G12-2_AbstractPrint.pdf

accesso aperto

Descrizione: Abstract pubblicato su volume cartaceo
Tipologia: Abstract
Licenza: PUBBLICO - Tutti i diritti riservati
Dimensione 100.07 kB
Formato Adobe PDF
100.07 kB Adobe PDF Visualizza/Apri
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11583/2675980
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo