A new replaceable hysteretic damper to better control seismic building damage consisting of two or more adjacent steel vertical elements connected to each other with continuous mild/low strength steel shear links, is proposed and investigated in this paper. New Dampers called Dissipative Columns (DC), continuously linked with X-shaped steel plates, provide additional stiffness and damping to a lateral system by using a basic and minimally invasive construction element: the column. Working in a way similar to coupled shear walls, the proposed element behavior is theoretically analyzed in linear and non-linear range. In fact, considering different restrained cases, a parametric analysis is developed in order both to evaluate the effect of the main geometrical and structural parameters and to provide the design capacity curves of this new damper. The DC can be considered as a new damping device easy to be installed to new as well to the existing buildings in order to protect them from seismic damage.

A new hysteretic dissipative column providing additional stiffness and damping / Palazzo, Bruno; Castaldo, Paolo; Marino, Ivana. - ELETTRONICO. - (2014), pp. 1-12. (Intervento presentato al convegno 2nd European Conference on Earthquake Engineering and Seismology (2ECEES) tenutosi a Istanbul nel august 25-29).

A new hysteretic dissipative column providing additional stiffness and damping

CASTALDO, PAOLO;
2014

Abstract

A new replaceable hysteretic damper to better control seismic building damage consisting of two or more adjacent steel vertical elements connected to each other with continuous mild/low strength steel shear links, is proposed and investigated in this paper. New Dampers called Dissipative Columns (DC), continuously linked with X-shaped steel plates, provide additional stiffness and damping to a lateral system by using a basic and minimally invasive construction element: the column. Working in a way similar to coupled shear walls, the proposed element behavior is theoretically analyzed in linear and non-linear range. In fact, considering different restrained cases, a parametric analysis is developed in order both to evaluate the effect of the main geometrical and structural parameters and to provide the design capacity curves of this new damper. The DC can be considered as a new damping device easy to be installed to new as well to the existing buildings in order to protect them from seismic damage.
2014
9786056270369
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11583/2664989
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo