The international standard ISO 140-5 for the measurement of the sound insulation of building façades will soon be replaced by the new standard ISO 16283-3. This revision includes the procedures for measurements at low frequencies down to 50 Hz. The uncertainty of façade sound insulation, in particular at low frequencies, was evaluated by a Round Robin Test, conducted in a full-scale experimental building at ITC-CNR. Each of the 10 teams involved in the RRT replicated the tests 5 times, for a total of 50 measurements. The different measurement positions inside the receiving room are compared. In particular, all the teams involved in the RRT assessed corner and center room positions; their energy average values according to ISO 16283-1 are considered and the relative uncertainty in terms of repeatability and in situ reproducibility standard deviations are compared with the ones measured and calculated following ISO 140-5.

Uncertainty of facade sound insulation measurements obtained by a round robin test: The influence of the low frequencies extension / Scrosati, Chiara; Scamoni, Fabio; Asdrubali, Francesco; D'Alessandro, Francesco; Moretti, Elisa; Astolfi, Arianna; Barbaresi, Luca; Cellai, Gianfranco; Secchi, Simone; Bella, Antonino Di; Pontarollo, Chiara Martina; Fausti, Patrizio; Prato, Andrea; Schenone, Corrado; Zambon, Giovanni; Angelini, Fabio. - CD-ROM. - (2015), pp. 1-8. (Intervento presentato al convegno 22nd International Congress on Sound and Vibration, ICSV 2015 tenutosi a Firenze, Italy nel 2015).

Uncertainty of facade sound insulation measurements obtained by a round robin test: The influence of the low frequencies extension

ASTOLFI, Arianna;PRATO, ANDREA;
2015

Abstract

The international standard ISO 140-5 for the measurement of the sound insulation of building façades will soon be replaced by the new standard ISO 16283-3. This revision includes the procedures for measurements at low frequencies down to 50 Hz. The uncertainty of façade sound insulation, in particular at low frequencies, was evaluated by a Round Robin Test, conducted in a full-scale experimental building at ITC-CNR. Each of the 10 teams involved in the RRT replicated the tests 5 times, for a total of 50 measurements. The different measurement positions inside the receiving room are compared. In particular, all the teams involved in the RRT assessed corner and center room positions; their energy average values according to ISO 16283-1 are considered and the relative uncertainty in terms of repeatability and in situ reproducibility standard deviations are compared with the ones measured and calculated following ISO 140-5.
2015
9788888942490
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11583/2658003
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo