Controlled rocking system has been proposed as an alternative design method to improve the structural performance of buildings. The rocking systems allow vertical and horizontal components to rotate freely at boundaries. When integrated in a frame system, rocking columns may reduce the yielding strength of the entire system. The acceleration response of yielding structure is proportional to its own weight, but it is limited by the yield strength. Thus using a rocking system, a limited acceleration response can be achieved. However, the displacements of a structure may become undesirably large due to lower strength, but they can be controlled adding damping. A simplified model of the rocking column was developed and verified through experimental tests conducted at the University at Buffalo. As a case study in this paper, the response of an analytical model of a scaled reinforced concrete frame structure is considered. Synthetic ground motions developed using the Barrier model are used as seismic input of the nonlinear dynamic analysis. Fragility analyses are performed to show the seismic performance of the original structures and the retrofitted structure with the rocking beam-column connections and viscous dampers. The analysis shows that the story accelerations can be limited by using rocking columns, while the story displacements can be controlled by using viscous dampers.

Fragility analysis of structures with controlled rocking beamcolumn connections and viscous dampers / Cimellaro, GIAN PAOLO; Roh, Hwasung. - ELETTRONICO. - 8:(2010), pp. 6405-6414. (Intervento presentato al convegno 9th US National and 10th Canadian Conference on Earthquake Engineering 2010, Including Papers from the 4th International Tsunami Symposium tenutosi a Toronto, ON, Canada nel 2010).

Fragility analysis of structures with controlled rocking beamcolumn connections and viscous dampers

CIMELLARO, GIAN PAOLO;
2010

Abstract

Controlled rocking system has been proposed as an alternative design method to improve the structural performance of buildings. The rocking systems allow vertical and horizontal components to rotate freely at boundaries. When integrated in a frame system, rocking columns may reduce the yielding strength of the entire system. The acceleration response of yielding structure is proportional to its own weight, but it is limited by the yield strength. Thus using a rocking system, a limited acceleration response can be achieved. However, the displacements of a structure may become undesirably large due to lower strength, but they can be controlled adding damping. A simplified model of the rocking column was developed and verified through experimental tests conducted at the University at Buffalo. As a case study in this paper, the response of an analytical model of a scaled reinforced concrete frame structure is considered. Synthetic ground motions developed using the Barrier model are used as seismic input of the nonlinear dynamic analysis. Fragility analyses are performed to show the seismic performance of the original structures and the retrofitted structure with the rocking beam-column connections and viscous dampers. The analysis shows that the story accelerations can be limited by using rocking columns, while the story displacements can be controlled by using viscous dampers.
2010
9781617388446
9781617388446
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11583/2656608
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo