The Basilica of San Francesco in Assisi endured stronger earthquakes for centuries before 1997 earthquake, which generated the collapse of the two vaults. Experts blame as possible reasons of collapse the damage cumulated from previous earthquakes and/or the retrofitting made to the structure over its lifetime. This article presents the history of the retrofit interventions of the Basilica through the centuries, focusing mainly on the roof, which has been subjected to three major restorations through its life. It is shown using simple analytical models that the cumulative effects of the changes made to the roof of the Basilica affected the structure's dynamic behavior in a negative manner, increasing the seismic loads on the existing structural members. In particular, the numerical results show that the 1958 roof intervention has stiffened the structure, redistributing the seismic loads on the facade and the transept. This overload might explain the collapse of the two Gothic vaults during 1997 earthquake.
The Dynamic Behavior of the Basilica of San Francesco in Assisi Using Simplified Analytical Models / Arcidiacono, V.; Cimellaro, GIAN PAOLO; Piermarini, E.; Ochsendorf, J.. - In: INTERNATIONAL JOURNAL OF ARCHITECTURAL HERITAGE. - ISSN 1558-3058. - ELETTRONICO. - 10:7(2016), pp. 938-953. [10.1080/15583058.2016.1158333]
The Dynamic Behavior of the Basilica of San Francesco in Assisi Using Simplified Analytical Models
CIMELLARO, GIAN PAOLO;
2016
Abstract
The Basilica of San Francesco in Assisi endured stronger earthquakes for centuries before 1997 earthquake, which generated the collapse of the two vaults. Experts blame as possible reasons of collapse the damage cumulated from previous earthquakes and/or the retrofitting made to the structure over its lifetime. This article presents the history of the retrofit interventions of the Basilica through the centuries, focusing mainly on the roof, which has been subjected to three major restorations through its life. It is shown using simple analytical models that the cumulative effects of the changes made to the roof of the Basilica affected the structure's dynamic behavior in a negative manner, increasing the seismic loads on the existing structural members. In particular, the numerical results show that the 1958 roof intervention has stiffened the structure, redistributing the seismic loads on the facade and the transept. This overload might explain the collapse of the two Gothic vaults during 1997 earthquake.File | Dimensione | Formato | |
---|---|---|---|
The Dynamic Behavior of the Basilica of San Francesco in Assisi Using Simplified Analytical Models.pdf
Open Access dal 05/03/2017
Descrizione: Articolo principale
Tipologia:
2. Post-print / Author's Accepted Manuscript
Licenza:
Pubblico - Tutti i diritti riservati
Dimensione
24.07 MB
Formato
Adobe PDF
|
24.07 MB | Adobe PDF | Visualizza/Apri |
Pubblicazioni consigliate
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.
https://hdl.handle.net/11583/2652917
Attenzione
Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo