In this paper, we have investigated the redundancy in array of Memristive-Biosensors and find optimum number for devices to accomplish reliable biodetection. Our results lead less expensive sensor and reduce the low-reproducibility of this memristive method for the detection of rabbit antigen. Several experiments have been performed with 17 memristive biosensors in several conditions. These conditions give us relevant informations about the overall behavior of memristor biosensor's array, after functionalization with antibody and exposure to antigen. The statistics made on different conditions, related to the standard deviation and the mean value of voltage gap, prove that such a sensor, with a minimum memristive biosensors in array, can be counted as reliable sensor for the detection of antigen.
Reliable redundancy with memristive-biosensors to achieve statistical significance in immunosensing / Lotfi, A.; Demarchi, Danilo; Puppo, F.; De Micheli, G.; Carrara, S.; Doucey, M. A.. - ELETTRONICO. - (2015), pp. 31-36. (Intervento presentato al convegno 2015 6th IEEE International Workshop on Advances in Sensors and Interfaces, IWASI 2015 tenutosi a Gallipoli, Italy nel 18-19 June 2015) [10.1109/IWASI.2015.7184969].
Reliable redundancy with memristive-biosensors to achieve statistical significance in immunosensing
DEMARCHI, DANILO;
2015
Abstract
In this paper, we have investigated the redundancy in array of Memristive-Biosensors and find optimum number for devices to accomplish reliable biodetection. Our results lead less expensive sensor and reduce the low-reproducibility of this memristive method for the detection of rabbit antigen. Several experiments have been performed with 17 memristive biosensors in several conditions. These conditions give us relevant informations about the overall behavior of memristor biosensor's array, after functionalization with antibody and exposure to antigen. The statistics made on different conditions, related to the standard deviation and the mean value of voltage gap, prove that such a sensor, with a minimum memristive biosensors in array, can be counted as reliable sensor for the detection of antigen.File | Dimensione | Formato | |
---|---|---|---|
07184969.pdf
accesso riservato
Descrizione: Lotfi IWASI2016
Tipologia:
2a Post-print versione editoriale / Version of Record
Licenza:
Non Pubblico - Accesso privato/ristretto
Dimensione
817.62 kB
Formato
Adobe PDF
|
817.62 kB | Adobe PDF | Visualizza/Apri Richiedi una copia |
Pubblicazioni consigliate
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.
https://hdl.handle.net/11583/2646248
Attenzione
Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo