An innovative base isolation system has been recently proposed for the retrofitting of existing buildings, in which the isolation layer is inserted under the building foundations so that the building, along with its foundations, is isolated from the surrounding soil. The isolation layer resides in closely-spaced micro-tunnels, constructed under the entire width of the building. These micro-tunnels, along with the trenches around the building, isolate the structure from the surrounding soil. The execution of these micro-tunnels is the most critical construction stage, because it may result in settlements which can damage the structure. In this paper, the behaviour of an existing structure, consisting of a masonry wall subjected to tunnelling-induced ground subsidence, is analysed. A parametric study is conducted using 2-D nonlinear finite element analyses to understand the role of key factors such as strength and stiffness of soil and masonry, roughness of soil-structure interface, excavation sequence of tunnels, wall dimensions and openings configuration. The study identifies the design variables which influence the most the risk of structural damage and suggests the most effective damage symptoms to be monitored during construction
Innovative technique for the base isolation of existing buildings / DE STEFANO, Alessandro; Clemente, Paolo; Invernizzi, Stefano; Matta, Emiliano; Quattrone, Antonino. - ELETTRONICO. - 1:(2015), pp. 377-387. (Intervento presentato al convegno COMPDYN 2015 5th ECCOMAS Thematic Conference on Computational Methods in Structural Dynamics and Earthquake Engineering tenutosi a Crete island, Greece nel 25-27 May 2015).
Innovative technique for the base isolation of existing buildings
DE STEFANO, Alessandro;INVERNIZZI, Stefano;MATTA, EMILIANO;QUATTRONE, ANTONINO
2015
Abstract
An innovative base isolation system has been recently proposed for the retrofitting of existing buildings, in which the isolation layer is inserted under the building foundations so that the building, along with its foundations, is isolated from the surrounding soil. The isolation layer resides in closely-spaced micro-tunnels, constructed under the entire width of the building. These micro-tunnels, along with the trenches around the building, isolate the structure from the surrounding soil. The execution of these micro-tunnels is the most critical construction stage, because it may result in settlements which can damage the structure. In this paper, the behaviour of an existing structure, consisting of a masonry wall subjected to tunnelling-induced ground subsidence, is analysed. A parametric study is conducted using 2-D nonlinear finite element analyses to understand the role of key factors such as strength and stiffness of soil and masonry, roughness of soil-structure interface, excavation sequence of tunnels, wall dimensions and openings configuration. The study identifies the design variables which influence the most the risk of structural damage and suggests the most effective damage symptoms to be monitored during constructionFile | Dimensione | Formato | |
---|---|---|---|
2015 De Stefano et al. COMPDYN.pdf
accesso aperto
Descrizione: Articolo principale
Tipologia:
2a Post-print versione editoriale / Version of Record
Licenza:
PUBBLICO - Tutti i diritti riservati
Dimensione
1.37 MB
Formato
Adobe PDF
|
1.37 MB | Adobe PDF | Visualizza/Apri |
Pubblicazioni consigliate
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.
https://hdl.handle.net/11583/2641510