The design of line-start Synchronous Reluctance machines is proposed, based on the state of the art of motors designed for closed loop, vector control. The guidelines for overcoming the dilemma between synchronization capability and steady state performance are given, with examples of good and bad design choices. The proposed solutions compared via finite element analysis with a competitor induction motor in terms of efficiency and power factor. The finite element calculations are finally validated via experiments on a laboratory prototype.
Design of a line-start synchronous reluctance motor / Gamba, Matteo; Pellegrino, GIAN - MARIO LUIGI; Vagati, Alfredo; Villata, Franco. - STAMPA. - (2013), pp. 648-655. (Intervento presentato al convegno 2013 International Electric Machines & Drives Conference tenutosi a Chicago, USA nel Maggio 2013) [10.1109/IEMDC.2013.6556163].
Design of a line-start synchronous reluctance motor
GAMBA, MATTEO;PELLEGRINO, GIAN - MARIO LUIGI;VAGATI, Alfredo;VILLATA, Franco
2013
Abstract
The design of line-start Synchronous Reluctance machines is proposed, based on the state of the art of motors designed for closed loop, vector control. The guidelines for overcoming the dilemma between synchronization capability and steady state performance are given, with examples of good and bad design choices. The proposed solutions compared via finite element analysis with a competitor induction motor in terms of efficiency and power factor. The finite element calculations are finally validated via experiments on a laboratory prototype.File | Dimensione | Formato | |
---|---|---|---|
PID2733637 - Pellegrino.pdf
accesso aperto
Tipologia:
2. Post-print / Author's Accepted Manuscript
Licenza:
PUBBLICO - Tutti i diritti riservati
Dimensione
1.13 MB
Formato
Adobe PDF
|
1.13 MB | Adobe PDF | Visualizza/Apri |
Pubblicazioni consigliate
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.
https://hdl.handle.net/11583/2518606
Attenzione
Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo