The aim of this work is to demonstrate the reliability of a simplified model in predicting the RH variation inside a room, taking into account the indoor material buffering effect. Starting from the characterization of the main hygroscopic properties of wood fiber an analysis of reliability of measured data for vapour permeability and sorption isotherm and their influence on numerical simulation is carried out. The determination of measured Moisture Buffer Value for the wood fiber is carried out through the simulation of the MBV test for uncoated elements. The results are compared to those from literature. The ventilation influence as room factor is taken into account for the whole room hygroscopic performance. More scenarios for different mechanical ventilation rates are foreseen considering a demand controlled and a fixed volume airflow. Simulations are carried out considering Turin weather data.

Impact of moisture buffering on indoor climate for mechanically ventilated offices / Ronzino, Amos; Neusser, M.; Wegerer, P.; Bednar, T.; Corrado, Vincenzo. - STAMPA. - (2013), pp. 358-366. (Intervento presentato al convegno VII Mediterranean Congress of Climatization (Climamed ’13) tenutosi a Istanbul nel 3- October, 2013).

Impact of moisture buffering on indoor climate for mechanically ventilated offices.

RONZINO, AMOS;CORRADO, Vincenzo
2013

Abstract

The aim of this work is to demonstrate the reliability of a simplified model in predicting the RH variation inside a room, taking into account the indoor material buffering effect. Starting from the characterization of the main hygroscopic properties of wood fiber an analysis of reliability of measured data for vapour permeability and sorption isotherm and their influence on numerical simulation is carried out. The determination of measured Moisture Buffer Value for the wood fiber is carried out through the simulation of the MBV test for uncoated elements. The results are compared to those from literature. The ventilation influence as room factor is taken into account for the whole room hygroscopic performance. More scenarios for different mechanical ventilation rates are foreseen considering a demand controlled and a fixed volume airflow. Simulations are carried out considering Turin weather data.
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11583/2517085
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo