The present paper analyzes the experimental results concerning the flow patterns and pressure drops in two-phase flow through an horizontal impacting T-junction, whose outlet pipes are aligned and perpendicular to the inlet pipe. The test section consists of plexiglass pipes with inner diameter of 10 mm. A mixture of water and air at ambient temperature and pressures up to 2.4 bar flows through the T-junction, with different splitting of flow rates in the two outlet branches; superficial velocities of air and water in the inlet pipe are varied up to a maximum of 35 m/s and 3.5 m/s respectively. The flow patterns occurring in the inlet and branch pipes were compared with the predictions of Baker’s and Taitel – Dukler’s maps. The pressure drops along the branches have been measured relatively to different splitting of the flow rate through the two branches and the pressure loss coefficients in the junction have been evaluated. Friction pressure drops have allowed us to evaluate two-phase friction multipliers, which have then been compared to the predictions of Lockhart-Martinelli, and Friedel correlations. Local pressure drops were extrapolated at the junction centre and analyzed; the two-phase multiplier has been evaluated and compared with the predictions of Chisholm correlation; the value of the empirical coefficient that minimizes the discrepancies has also been evaluated.
Experimental Study on the Flow Patterns and Two-phase Pressure Drops in a Horizontal Impacting T- Junction / Bertani, Cristina; Malandrone, Mario; Panella, Bruno. - In: JOURNAL OF PHYSICS. CONFERENCE SERIES. - ISSN 1742-6588. - STAMPA. - 501:(2014), pp. 1-10. (Intervento presentato al convegno 31th UIT National Heat Transfer Conference tenutosi a Como nel June 25- 27) [10.1088/1742-6596/501/1/012013].
Experimental Study on the Flow Patterns and Two-phase Pressure Drops in a Horizontal Impacting T- Junction
BERTANI, CRISTINA;MALANDRONE, Mario;PANELLA, BRUNO
2014
Abstract
The present paper analyzes the experimental results concerning the flow patterns and pressure drops in two-phase flow through an horizontal impacting T-junction, whose outlet pipes are aligned and perpendicular to the inlet pipe. The test section consists of plexiglass pipes with inner diameter of 10 mm. A mixture of water and air at ambient temperature and pressures up to 2.4 bar flows through the T-junction, with different splitting of flow rates in the two outlet branches; superficial velocities of air and water in the inlet pipe are varied up to a maximum of 35 m/s and 3.5 m/s respectively. The flow patterns occurring in the inlet and branch pipes were compared with the predictions of Baker’s and Taitel – Dukler’s maps. The pressure drops along the branches have been measured relatively to different splitting of the flow rate through the two branches and the pressure loss coefficients in the junction have been evaluated. Friction pressure drops have allowed us to evaluate two-phase friction multipliers, which have then been compared to the predictions of Lockhart-Martinelli, and Friedel correlations. Local pressure drops were extrapolated at the junction centre and analyzed; the two-phase multiplier has been evaluated and compared with the predictions of Chisholm correlation; the value of the empirical coefficient that minimizes the discrepancies has also been evaluated.File | Dimensione | Formato | |
---|---|---|---|
31_UIT_COMO.pdf
accesso aperto
Descrizione: COMO_2013
Tipologia:
2. Post-print / Author's Accepted Manuscript
Licenza:
Creative commons
Dimensione
840.31 kB
Formato
Adobe PDF
|
840.31 kB | Adobe PDF | Visualizza/Apri |
Pubblicazioni consigliate
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.
https://hdl.handle.net/11583/2513778
Attenzione
Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo