Erroneous vocal behavior of teachers and their changes in the voice production due to poor acoustics in classrooms can be investigated through recently developed voice-monitoring devices. These devices are portable analyzers that use a miniature contact-microphone glued to the jugular notch in order to sense the skin acceleration level due to the vibration of the vocal folds. They estimate the Sound Pressure Level (SPL) at a certain distance from the speaker’s mouth provided that a preliminary calibration procedure is performed, the fundamental frequency and the time dose. Two different devices are compared in this work: the former is a commercial device, whose phonation sensor is a small accelerometer; the latter, recently developed by the authors, uses an electret condenser microphone to sense the skin acceleration level. SPL and fundamental frequency are estimated over fixed-length frames and the results that refer to a sample of 25 primary school teachers and a university professor are analyzed. The duration of the voice and pause periods is investigated in order to detect the peaks of occurrence and accumulation in different conditions of reverberation. A method for the detection and analysis of the emphatic speech is also proposed.

Influence of classroom acoustics on the vocal behavior of teacers / Astolfi, Arianna; Carullo, Alessio; Vallan, Alberto; Pavese, Lorenzo. - In: PROCEEDINGS OF MEETINGS ON ACOUSTICS. - ISSN 1939-800X. - STAMPA. - 19, 040123:(2013), pp. 1-9. (Intervento presentato al convegno 21st International Congress on Acoustics tenutosi a Montreal (CAN) nel 2-7 June 2013) [10.1121/1.4800427].

Influence of classroom acoustics on the vocal behavior of teacers

ASTOLFI, Arianna;CARULLO, Alessio;VALLAN, Alberto;PAVESE, LORENZO
2013

Abstract

Erroneous vocal behavior of teachers and their changes in the voice production due to poor acoustics in classrooms can be investigated through recently developed voice-monitoring devices. These devices are portable analyzers that use a miniature contact-microphone glued to the jugular notch in order to sense the skin acceleration level due to the vibration of the vocal folds. They estimate the Sound Pressure Level (SPL) at a certain distance from the speaker’s mouth provided that a preliminary calibration procedure is performed, the fundamental frequency and the time dose. Two different devices are compared in this work: the former is a commercial device, whose phonation sensor is a small accelerometer; the latter, recently developed by the authors, uses an electret condenser microphone to sense the skin acceleration level. SPL and fundamental frequency are estimated over fixed-length frames and the results that refer to a sample of 25 primary school teachers and a university professor are analyzed. The duration of the voice and pause periods is investigated in order to detect the peaks of occurrence and accumulation in different conditions of reverberation. A method for the detection and analysis of the emphatic speech is also proposed.
File in questo prodotto:
File Dimensione Formato  
PMA040123(1).pdf

accesso aperto

Tipologia: 2. Post-print / Author's Accepted Manuscript
Licenza: PUBBLICO - Tutti i diritti riservati
Dimensione 757.82 kB
Formato Adobe PDF
757.82 kB Adobe PDF Visualizza/Apri
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11583/2507894
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo