The antenna scattering (S‐matrix) or impedance matrix at location where the antenna is connected to the power system is of crucial importance to assess compliance with power handling requirements and to design the tuning‐and‐matching system. The electrical behaviour of an Ion Cyclotron Resonance Heating (ICRH) ITER antenna in front of an infinite isotropic load was assessed numerically using the HFSSR and TOPICA codes for comparison. The calculations were performed at 45 MHz, for various thicknesses of the vacuum layer, various relative permittivities ε′ for dielectric medium without losses (ε″ = 0), ε′ ranging from 81 to 1000 and for various conductive losses ε″ = σ/ε0⋅ω, for electrolyte medium (ε′ = 81), ε″ ranging from 0 to 1000. The numerical results obtained with TOPICA and HFSS codes show a good overall agreement in case of vacuum, dielectric and electrolyte mediums. The best absorption of the fast magneto‐sonic (Alfven) waves into the loads (i.e. the minimum of the module of antenna input reflection coefficient S11) is obtained around ε′ = 400 for dielectric medium and around ε″ = 400 for electrolyte case.
Electromagnetic Modelling of Dielectric loads in front of an ICRH ITER array using TOPICA and HFSS codes for comparison / El Khaldi, M.; Milanesio, Daniele; Maggiora, Riccardo; Magne, R.; Vulliez, K.. - In: AIP CONFERENCE PROCEEDINGS. - ISSN 0094-243X. - STAMPA. - 1187:(2009), pp. 273-276. (Intervento presentato al convegno 18th Topical Conference on Radio Frequency Power in Plasmas tenutosi a Ghent, Belgium nel 24–26 June 2009) [10.1063/1.3273746].
Electromagnetic Modelling of Dielectric loads in front of an ICRH ITER array using TOPICA and HFSS codes for comparison
MILANESIO, DANIELE;MAGGIORA, Riccardo;
2009
Abstract
The antenna scattering (S‐matrix) or impedance matrix at location where the antenna is connected to the power system is of crucial importance to assess compliance with power handling requirements and to design the tuning‐and‐matching system. The electrical behaviour of an Ion Cyclotron Resonance Heating (ICRH) ITER antenna in front of an infinite isotropic load was assessed numerically using the HFSSR and TOPICA codes for comparison. The calculations were performed at 45 MHz, for various thicknesses of the vacuum layer, various relative permittivities ε′ for dielectric medium without losses (ε″ = 0), ε′ ranging from 81 to 1000 and for various conductive losses ε″ = σ/ε0⋅ω, for electrolyte medium (ε′ = 81), ε″ ranging from 0 to 1000. The numerical results obtained with TOPICA and HFSS codes show a good overall agreement in case of vacuum, dielectric and electrolyte mediums. The best absorption of the fast magneto‐sonic (Alfven) waves into the loads (i.e. the minimum of the module of antenna input reflection coefficient S11) is obtained around ε′ = 400 for dielectric medium and around ε″ = 400 for electrolyte case.Pubblicazioni consigliate
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.
https://hdl.handle.net/11583/2303007
Attenzione
Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo