The present research concerns the experimental investigation of dividing flow rates and pressure drops in a plexiglas tee junction with horizontal inlet, run, and branch sides using air-water mixtures. The branch stream is orthogonal to the inlet and run streams. The pipes forming the tee junction are about 1 m long, their inner diameter is 10 mm. The flow loop was supplied with compressed air and water through a mixing tee, at 1.5 bar and approximately ambient temperature. Air flow rate ranges from 0.3 to 9 Nl/s, water flow rate from 14.5 to 58 g/s, air superficial velocity from 1.5 to 47 m/s, water superficial velocity from 0.2 to 0.7 m/s and flow quality from 0.6% to 43%. The extraction ratio (branch flow rate/inlet flow rate) ranges from 0 to 1. Wavy stratified, slug, churn and annular flow patterns, as well as transition flow patterns have been obtained. Experimental values of flow rate, phases superficial velocity, extraction ratio and pressure drops across the tee junction pipes are here reported. Pressure drop test results across the inlet and branch pipes have also been compared with predicted ones. [120511.EG Pseudo-ISBN 979-88-7741-156-2 in luogo di 88-7741-1569-1 riportato dalla pubblicazione, ma errato (v. catalogo SBN) e quindi non inseribile in UGOV.]

Pressure Drop and Phase Separation in a Horizontal T-Junction / Bertani, Cristina; Malandrone, Mario; Panella, Bruno; Quaranta, A.. - (2006), pp. 267-274. (Intervento presentato al convegno XXIV Congresso nazionale UIT sulla Trasmissione del Calore tenutosi a Napoli, Italy nel 21-23 Giugno 2006).

Pressure Drop and Phase Separation in a Horizontal T-Junction

BERTANI, CRISTINA;MALANDRONE, Mario;PANELLA, BRUNO;
2006

Abstract

The present research concerns the experimental investigation of dividing flow rates and pressure drops in a plexiglas tee junction with horizontal inlet, run, and branch sides using air-water mixtures. The branch stream is orthogonal to the inlet and run streams. The pipes forming the tee junction are about 1 m long, their inner diameter is 10 mm. The flow loop was supplied with compressed air and water through a mixing tee, at 1.5 bar and approximately ambient temperature. Air flow rate ranges from 0.3 to 9 Nl/s, water flow rate from 14.5 to 58 g/s, air superficial velocity from 1.5 to 47 m/s, water superficial velocity from 0.2 to 0.7 m/s and flow quality from 0.6% to 43%. The extraction ratio (branch flow rate/inlet flow rate) ranges from 0 to 1. Wavy stratified, slug, churn and annular flow patterns, as well as transition flow patterns have been obtained. Experimental values of flow rate, phases superficial velocity, extraction ratio and pressure drops across the tee junction pipes are here reported. Pressure drop test results across the inlet and branch pipes have also been compared with predicted ones. [120511.EG Pseudo-ISBN 979-88-7741-156-2 in luogo di 88-7741-1569-1 riportato dalla pubblicazione, ma errato (v. catalogo SBN) e quindi non inseribile in UGOV.]
2006
9798877411562
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11583/1501977
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo