This paper exposes the performance of field oriented control for induction motors drives based on average motor parameters, rather than individual ones. The average parameters for a group of industrial motors of small size (7.5 kW, 50 Hz, 4 poles, 380 V) have been evaluated, with reference to field oriented control. Averaged field oriented controls based on the mean values of motors parameters, obtained by statistical analysis or from motor data sheets, have been set up. Test criteria, chosen to evaluate the control performance, are presented and discussed.

Induction motors field oriented control based on averaged parameters / Boglietti, Aldo; P., Ferraris; Pastorelli, MICHELE ANGELO; C., Zimaglia. - 1:(1994), pp. 81-87. (Intervento presentato al convegno IEEE Industry Applications Society Annual Meeting tenutosi a Denver (USA) nel 2-6 Oct 1994) [10.1109/IAS.1994.345495].

Induction motors field oriented control based on averaged parameters

BOGLIETTI, Aldo;PASTORELLI, MICHELE ANGELO;
1994

Abstract

This paper exposes the performance of field oriented control for induction motors drives based on average motor parameters, rather than individual ones. The average parameters for a group of industrial motors of small size (7.5 kW, 50 Hz, 4 poles, 380 V) have been evaluated, with reference to field oriented control. Averaged field oriented controls based on the mean values of motors parameters, obtained by statistical analysis or from motor data sheets, have been set up. Test criteria, chosen to evaluate the control performance, are presented and discussed.
1994
0780319931
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11583/1407571
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo