Although comparisons between silicon (Si) and silicon-carbide (SiC) power devices are widely available, several aspects relevant to industrial motor drives—such as the evaluation of realistic AC losses under PWM, layout-induced overvoltages, and retrofitting feasibility—have not yet been analyzed in a systematic and system-level manner. This article addresses these gaps using a custom industrial twin-inverter platform in which all parasitics, cable connections, thermal paths, and PCB layouts are kept identical across all-Si, Si–SiC, and all-SiC power modules. An enhanced opposition method is implemented to extract conduction and switching losses under sinusoidal PWM. Results show that Si–SiC modules substantially reduce switching losses relative to all-Si, while maintaining similar conduction behavior and moderate dv/dt. All-SiC modules provide the lowest switching energy but introduce severe overvoltages both at the load terminals and, unexpectedly, at the inverter output terminals due to unavoidable connection wiring. These effects limit retrofitting feasibility in existing installations. Overall, hybrid Si–SiC technology provides the most practical balance between performance and compatibility, whereas all-SiC devices require system-level codesign of cabling, filtering, and insulation.
A System-Level Comparison of All-Si, Si–SiC, and All-SiC Power Modules in Industrial Motor Drives / Ruffo, R., Cirimele, V., Guglielmi, P., Shimizu, E.A.A.T.. - In: IEEE OPEN JOURNAL OF INDUSTRY APPLICATIONS. - ISSN 2644-1241. - 7:(2026), pp. 1179-1192. [10.1109/OJIA.2026.3747194]
A System-Level Comparison of All-Si, Si–SiC, and All-SiC Power Modules in Industrial Motor Drives
P. Guglielmi;
2026
Abstract
Although comparisons between silicon (Si) and silicon-carbide (SiC) power devices are widely available, several aspects relevant to industrial motor drives—such as the evaluation of realistic AC losses under PWM, layout-induced overvoltages, and retrofitting feasibility—have not yet been analyzed in a systematic and system-level manner. This article addresses these gaps using a custom industrial twin-inverter platform in which all parasitics, cable connections, thermal paths, and PCB layouts are kept identical across all-Si, Si–SiC, and all-SiC power modules. An enhanced opposition method is implemented to extract conduction and switching losses under sinusoidal PWM. Results show that Si–SiC modules substantially reduce switching losses relative to all-Si, while maintaining similar conduction behavior and moderate dv/dt. All-SiC modules provide the lowest switching energy but introduce severe overvoltages both at the load terminals and, unexpectedly, at the inverter output terminals due to unavoidable connection wiring. These effects limit retrofitting feasibility in existing installations. Overall, hybrid Si–SiC technology provides the most practical balance between performance and compatibility, whereas all-SiC devices require system-level codesign of cabling, filtering, and insulation.Pubblicazioni consigliate
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.
https://hdl.handle.net/11583/3018200
Attenzione
Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo