Efficient removal of neutral particles from the divertor region is essential for maintaining acceptable plasma conditions and ensuring reliable operation of future fusion reactors. In the present work, the neutral gas dynamics in the sub-divertor region of the DEMO low aspect ratio (LAR) divertor are investigated using three-dimensional Direct Simulation Monte Carlo (DSMC) simulations. A 3D complex model of one divertor sector is employed to quantify particle exhaust through the pumping openings, neutral leakage through the toroidal and poloidal gaps, and the corresponding pressure and temperature distributions. The influence of the divertor entrance pressure and the effective pumping probability is systematically examined, together with the effect of asymmetric pressure conditions at the divertor entry gaps. The results show that the pumping probability is the dominant parameter controlling the exhaust performance, increasing the pumped particle flux while reducing neutral leakage, particularly through the toroidal gaps. Changes in the divertor entrance pressure mainly affect the absolute pressure levels, with only a limited influence on the overall flow field. Simulations with asymmetric injection pressures indicate that pressure imbalances between the two divertor entry gaps have moderate effect on the neutral transport. Over the investigated conditions, 57.9%–86.4% of the incoming neutral particles return to the plasma region through the divertor entry gaps, while the pumped fraction ranges from 1.74% to 22% of the incoming flux, increasing with both the pumping probability and the injection pressure. To complement the DSMC analysis, a reduced-order conductance model is developed for rapid engineering assessments. The model captures the overall pressure distribution and DSMC trends with an average absolute deviation of ∼29% in only a few seconds, making it suitable for preliminary design studies. Overall, these results quantify neutral gas transport and pumping performance in the DEMO LAR divertor and support particle exhaust development.

First assessment of neutral gas transport in the EU DEMO low aspect ratio divertor / Tantos, C., Litovoli, F., Strobel, H., Marzullo, D., You, J.-., Subba, F., Mazzone, G., Moscheni, M.. - In: PLASMA PHYSICS AND CONTROLLED FUSION. - ISSN 0741-3335. - 68:11(2026). [10.1088/1361-6587/aebd19]

First assessment of neutral gas transport in the EU DEMO low aspect ratio divertor

Subba, F;Mazzone, G;Moscheni, M
2026

Abstract

Efficient removal of neutral particles from the divertor region is essential for maintaining acceptable plasma conditions and ensuring reliable operation of future fusion reactors. In the present work, the neutral gas dynamics in the sub-divertor region of the DEMO low aspect ratio (LAR) divertor are investigated using three-dimensional Direct Simulation Monte Carlo (DSMC) simulations. A 3D complex model of one divertor sector is employed to quantify particle exhaust through the pumping openings, neutral leakage through the toroidal and poloidal gaps, and the corresponding pressure and temperature distributions. The influence of the divertor entrance pressure and the effective pumping probability is systematically examined, together with the effect of asymmetric pressure conditions at the divertor entry gaps. The results show that the pumping probability is the dominant parameter controlling the exhaust performance, increasing the pumped particle flux while reducing neutral leakage, particularly through the toroidal gaps. Changes in the divertor entrance pressure mainly affect the absolute pressure levels, with only a limited influence on the overall flow field. Simulations with asymmetric injection pressures indicate that pressure imbalances between the two divertor entry gaps have moderate effect on the neutral transport. Over the investigated conditions, 57.9%–86.4% of the incoming neutral particles return to the plasma region through the divertor entry gaps, while the pumped fraction ranges from 1.74% to 22% of the incoming flux, increasing with both the pumping probability and the injection pressure. To complement the DSMC analysis, a reduced-order conductance model is developed for rapid engineering assessments. The model captures the overall pressure distribution and DSMC trends with an average absolute deviation of ∼29% in only a few seconds, making it suitable for preliminary design studies. Overall, these results quantify neutral gas transport and pumping performance in the DEMO LAR divertor and support particle exhaust development.
File in questo prodotto:
File Dimensione Formato  
Tantos_2026_Plasma_Phys._Control._Fusion_68_115015.pdf

accesso aperto

Tipologia: 2a Post-print versione editoriale / Version of Record
Licenza: Creative commons
Dimensione 2.56 MB
Formato Adobe PDF
2.56 MB Adobe PDF Visualizza/Apri
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11583/3017987