A standard titanium grit-blasted acid-etched (GBAE) surface, a patterned titanium laser surface (LS) and the same LS treated with atmospheric plasma (Plasma-LS) were characterized morphologically and chemically through Scanning Electron Microscope/Energy Dispersive X-ray analysis. According to the X-ray Photoelectron Spectroscopy C, O, and N were the most abundant contaminants on the three titania surfaces. Based on multi-parametric surface measurements, including the developed interfacial area ratio (Sdr), LS (Sdr = 105.00 +/- 3.00%) and Plasma-LS (Sdr = 50.00 +/- 3.00%) exhibited significantly higher values compared to GBAE (Sdr = 3.05 +/- 0.11%). As for the optical contact angle measurements, Plasma-LS did not show detectable angles, while LS presented greater affinity to both water and diiodomethane compared to GBAE. Plasma-LS displayed the highest total surface energy (73mJ/m2), almost equally distributing the polar (gamma P) and dispersive (gamma D) components, while gamma P/gamma D ratio was close to 1/3 in GBAE and LS. Plasma-LS adsorbed significantly the highest amount of bovine serum albumin. At 24 h, on GBAE, cells spread more and were more circular than on LS and Plasma-LS. Based on the viability assay, Plasma-LS, outperformed significantly GBAE and LS, after 3 and 7 days of culture. Further studies and clinical trials are required to establish the efficacy and safety of this acid-free surface modification for osseointegration.

In vitro evaluation of atmospheric plasma treatment for enhancing the biological response of a laser textured titanium dental implant surface / Mosca Balma, A., Meinardi, S., Pedraza, R., Orrico, C., Roato, I., Mandracci, P., Ribotta, L., Giura, A., Pisani, M., Genova, T., D'Angelo, D., Mussano, F.. - In: APPLIED SURFACE SCIENCE. - ISSN 0169-4332. - 735:(2026). [10.1016/j.apsusc.2026.166735]

In vitro evaluation of atmospheric plasma treatment for enhancing the biological response of a laser textured titanium dental implant surface

Mandracci P.;
2026

Abstract

A standard titanium grit-blasted acid-etched (GBAE) surface, a patterned titanium laser surface (LS) and the same LS treated with atmospheric plasma (Plasma-LS) were characterized morphologically and chemically through Scanning Electron Microscope/Energy Dispersive X-ray analysis. According to the X-ray Photoelectron Spectroscopy C, O, and N were the most abundant contaminants on the three titania surfaces. Based on multi-parametric surface measurements, including the developed interfacial area ratio (Sdr), LS (Sdr = 105.00 +/- 3.00%) and Plasma-LS (Sdr = 50.00 +/- 3.00%) exhibited significantly higher values compared to GBAE (Sdr = 3.05 +/- 0.11%). As for the optical contact angle measurements, Plasma-LS did not show detectable angles, while LS presented greater affinity to both water and diiodomethane compared to GBAE. Plasma-LS displayed the highest total surface energy (73mJ/m2), almost equally distributing the polar (gamma P) and dispersive (gamma D) components, while gamma P/gamma D ratio was close to 1/3 in GBAE and LS. Plasma-LS adsorbed significantly the highest amount of bovine serum albumin. At 24 h, on GBAE, cells spread more and were more circular than on LS and Plasma-LS. Based on the viability assay, Plasma-LS, outperformed significantly GBAE and LS, after 3 and 7 days of culture. Further studies and clinical trials are required to establish the efficacy and safety of this acid-free surface modification for osseointegration.
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11583/3012311
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo