This paper describes the developed set-up and the characterization approaches to realize full two-port, calibrated scattering parameters measurements at cryogenic temperatures, providing a complete uncertainty budget. The system developed at the Istituto Nazionale di Ricerca Metrologica (INRiM, Italy), exploits the Short-Open-Load-Reciprocal technique, to realize error corrected cryogenic measurements with single cooling cycle. The system operates at temperatures down to the mK range, in the band 4-12 GHz in coaxial line. Calibration standards are referred to traceable room temperature measurements, while a numerical approach is used to evaluate the artifact response shift from room temperature values, and derive key information to enable full measurement uncertainty budget. Moreover, relevant measurement uncertainty contributions are evaluated according to internationally agreed procedures, and a comprehensive uncertainty budget is presented. Test measurements on a 20 dB attenuator are shown as an example. An attenuation value of 20.70 +/- 0.08 dB (95% confidence interval) was obtained at 6 GHz.

Measurement and Calibration Approaches for Two-Port Scattering Parameters at mK Temperatures / Oberto, Luca; Shokrolahzade, Ehsan; Enrico, Emanuele; Fasolo, Luca; Celotto, Andrea; Galvano, Bernardo; Alocco, Alessandro; Terzi, Paolo; Mubarak, Faisal A.; Spirito, Marco. - (2024).

Measurement and Calibration Approaches for Two-Port Scattering Parameters at mK Temperatures

Oberto,Luca;Enrico, Emanuele;Celotto,Andrea;Alocco,Alessandro;
2024

Abstract

This paper describes the developed set-up and the characterization approaches to realize full two-port, calibrated scattering parameters measurements at cryogenic temperatures, providing a complete uncertainty budget. The system developed at the Istituto Nazionale di Ricerca Metrologica (INRiM, Italy), exploits the Short-Open-Load-Reciprocal technique, to realize error corrected cryogenic measurements with single cooling cycle. The system operates at temperatures down to the mK range, in the band 4-12 GHz in coaxial line. Calibration standards are referred to traceable room temperature measurements, while a numerical approach is used to evaluate the artifact response shift from room temperature values, and derive key information to enable full measurement uncertainty budget. Moreover, relevant measurement uncertainty contributions are evaluated according to internationally agreed procedures, and a comprehensive uncertainty budget is presented. Test measurements on a 20 dB attenuator are shown as an example. An attenuation value of 20.70 +/- 0.08 dB (95% confidence interval) was obtained at 6 GHz.
2024
Measurement and Calibration Approaches for Two-Port Scattering Parameters at mK Temperatures / Oberto, Luca; Shokrolahzade, Ehsan; Enrico, Emanuele; Fasolo, Luca; Celotto, Andrea; Galvano, Bernardo; Alocco, Alessandro; Terzi, Paolo; Mubarak, Faisal A.; Spirito, Marco. - (2024).
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11583/3004486
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo