The impact of hemolysis during microaxial flow pump (mAFP; Impella, Danvers, Massachusetts, US) support on early outcomes after durable left ventricular assist device (d-LVAD) implantation is unknown. Three hundred and eleven consecutive patients undergoing d-LVAD implantation after mAFP support (Impella 5.0/5.5 72.3%) were retrospectively included. The incidence and predictors of hemolysis (plasma-free hemoglobin >20 mg/dl or lactic dehydrogenase (LDH) >2.5-fold the upper reference limit) before d-LVAD implantation were assessed, along with its impact on early post-d-LVAD outcomes. The primary outcome was a composite of hemocompatibility-related adverse events (HRAEs: stroke/gastrointestinal bleeding/ pump thrombosis). Hemolysis occurred in 40.8%. Impella 2.5/CP versus 5.0/5.5 was the single independent predictor of hemolysis (adj-hazard ratio [HR] = 2.68, 95% confidence interval [CI] = 1.04-6.94, p = 0.031). Post-d-LVAD HRAEs occurred more frequently among patients with hemolysis (31.9% vs. 20.6%; p = 0.041), mainly driven by hemorrhagic stroke and gastrointestinal bleeding. At multivariate analysis, hemolysis remained independently associated with HRAEs (adj-HR = 1.62, 95% CI = 1.02-2.58; p = 0.041). Patients with hemolysis were more likely to need a temporary right ventricular assist device following d-LVAD implantation (28.3% vs. 16.8%; p = 0.012), with no difference in mortality (23.6% vs. 21.2%; p = 0.355). In conclusion, among patients undergoing d-LVAD implantation with mAFP bridge, hemolysis is common, occurs more frequently among patients supported with Impella 2.5/CP, and is an independent predictor of post-d-LVAD HRAEs.
Impact of Hemolysis During Microaxial Flow Pump Support on Early Outcomes After Durable Left Ventricular Assist Device Implantation / Gallone, G., Lewin, D., Spitaleri, A., Rojas Hernandez, S., Bernhardt, A., Billion, M., Meyer, A., Netuka, I., Kooij, J., Pieri, M., Szymanski, M., Moeller, C., Akhyari, P., Jawad, K., Krasivskyi, I., Schmack, B., Färber, G., Medina, M., Haneya, A., Zimpfer, D., et al.. - In: ASAIO JOURNAL. - ISSN 1058-2916. - 72:3(2026), pp. 191-198. [10.1097/mat.0000000000002451]
Impact of Hemolysis During Microaxial Flow Pump Support on Early Outcomes After Durable Left Ventricular Assist Device Implantation
Spitaleri, Antonio;Rinaldi, Mauro;
2026
Abstract
The impact of hemolysis during microaxial flow pump (mAFP; Impella, Danvers, Massachusetts, US) support on early outcomes after durable left ventricular assist device (d-LVAD) implantation is unknown. Three hundred and eleven consecutive patients undergoing d-LVAD implantation after mAFP support (Impella 5.0/5.5 72.3%) were retrospectively included. The incidence and predictors of hemolysis (plasma-free hemoglobin >20 mg/dl or lactic dehydrogenase (LDH) >2.5-fold the upper reference limit) before d-LVAD implantation were assessed, along with its impact on early post-d-LVAD outcomes. The primary outcome was a composite of hemocompatibility-related adverse events (HRAEs: stroke/gastrointestinal bleeding/ pump thrombosis). Hemolysis occurred in 40.8%. Impella 2.5/CP versus 5.0/5.5 was the single independent predictor of hemolysis (adj-hazard ratio [HR] = 2.68, 95% confidence interval [CI] = 1.04-6.94, p = 0.031). Post-d-LVAD HRAEs occurred more frequently among patients with hemolysis (31.9% vs. 20.6%; p = 0.041), mainly driven by hemorrhagic stroke and gastrointestinal bleeding. At multivariate analysis, hemolysis remained independently associated with HRAEs (adj-HR = 1.62, 95% CI = 1.02-2.58; p = 0.041). Patients with hemolysis were more likely to need a temporary right ventricular assist device following d-LVAD implantation (28.3% vs. 16.8%; p = 0.012), with no difference in mortality (23.6% vs. 21.2%; p = 0.355). In conclusion, among patients undergoing d-LVAD implantation with mAFP bridge, hemolysis is common, occurs more frequently among patients supported with Impella 2.5/CP, and is an independent predictor of post-d-LVAD HRAEs.| File | Dimensione | Formato | |
|---|---|---|---|
|
impact_of_hemolysis_during_microaxial_flow_pump.3.pdf
accesso aperto
Tipologia:
2a Post-print versione editoriale / Version of Record
Licenza:
Pubblico - Tutti i diritti riservati
Dimensione
1.06 MB
Formato
Adobe PDF
|
1.06 MB | Adobe PDF | Visualizza/Apri |
Pubblicazioni consigliate
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.
https://hdl.handle.net/11583/3000856
