Corrosion behaviour of commercially pure Zn during immersion up to 4 weeks is studied in three different solutions mimicking physiological environment, i.e. Hanks’ Balance Salt Solution (HBSS), Dulbecco’s modified Eagles’ medium (DMEM) and DMEM with 10 % of fetal bovine serum (DMEM + 10 % FBS). Morphological characterizations, electrochemical tests, weight loss, and ion release measurements show that the corrosion mechanism is significantly affected by the physiological solution. In HBSS a phosphate-based conversion layer forms resulting to significantly slow down the corrosion rate, while in DMEM an intergranular corrosion occurs. The latter is hindered due to the presence of proteins from the fetal bovine serum in DMEM+FBS. The main cathodic process is oxygen reduction in all physiological media. Direct estimate of corrosion rate by gravimetric measurements revealed that zinc dissolution becomes very slow after two weeks of immersion in the employed physiological thus suggesting that zinc is not suitable for the fabrication of biodegradable implants in static fluidic condition.

Following Zn corrosion during long term immersion test in physiological solutions to establish the potential of zinc as biodegradable prosthetic material / Pupillo, D.; Di Franco, F.; Iannucci, L.; Grassini, S.; Virtanen, S.; Santamaria, M.. - In: ELECTROCHIMICA ACTA. - ISSN 0013-4686. - 531:(2025). [10.1016/j.electacta.2025.146411]

Following Zn corrosion during long term immersion test in physiological solutions to establish the potential of zinc as biodegradable prosthetic material

Pupillo, D.;Iannucci, L.;Grassini, S.;
2025

Abstract

Corrosion behaviour of commercially pure Zn during immersion up to 4 weeks is studied in three different solutions mimicking physiological environment, i.e. Hanks’ Balance Salt Solution (HBSS), Dulbecco’s modified Eagles’ medium (DMEM) and DMEM with 10 % of fetal bovine serum (DMEM + 10 % FBS). Morphological characterizations, electrochemical tests, weight loss, and ion release measurements show that the corrosion mechanism is significantly affected by the physiological solution. In HBSS a phosphate-based conversion layer forms resulting to significantly slow down the corrosion rate, while in DMEM an intergranular corrosion occurs. The latter is hindered due to the presence of proteins from the fetal bovine serum in DMEM+FBS. The main cathodic process is oxygen reduction in all physiological media. Direct estimate of corrosion rate by gravimetric measurements revealed that zinc dissolution becomes very slow after two weeks of immersion in the employed physiological thus suggesting that zinc is not suitable for the fabrication of biodegradable implants in static fluidic condition.
File in questo prodotto:
File Dimensione Formato  
ChemSusChem - 2024 - Morante - Unraveling the Role of CuO in CuxO TiO2 Photocatalyst for the Direct Propylene Epoxidation.pdf

accesso aperto

Tipologia: 2a Post-print versione editoriale / Version of Record
Licenza: Creative commons
Dimensione 5.11 MB
Formato Adobe PDF
5.11 MB Adobe PDF Visualizza/Apri
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11583/3000027