Within the Best Estimate Plus Uncertainty framework for the safety analysis of Nuclear Power Plants, the quantification of the uncertainties affecting the Thermal-Hydraulics (T-H) codes used is crucial. For this, Inverse Uncertainty Quantification (IUQ) methodologies are being developed for determining the probability density functions of relevant T-H codes input parameters, based on experimental data from Separate Effect Tests (SETs) experimental facilities. In practice, IUQ is challenged by the large range of variability of the experimental data in terms of Initial and Boundary Conditions (ICs & BCs), because the experimental campaigns are designed to cover the widest possible domain of conditions with the smallest number of experiments, so that same or similar ICs and BCs are seldomly repeated. To address this issue, we propose to use global sensitivity analysis, to tailor the IUQ on specific sub-regions described by segmented ICs & BCs domains. The methodology proposed is exemplified on two SETs, namely Sozzi-Sutherland and Super Moby Dick, whose experimental databases have been made available in the ATRIUM (Application Tests for Realization of Inverse Uncertainty quantification and validation Methodologies in thermal hydraulics) project promoted by the OECD/NEA/CSNI. The results obtained are superior to those of traditional IUQ methodologies for models highly sensitive to ICs & BCs.

Global Sensitivity Analysis for Segmented Inverse Uncertainty Quantification in the Safety Analysis of Nuclear Power Plants / Di Maio, F.; Matteo Coscia, T.; Pedroni, N.; Bersano, A.; Mascari, F.; Zio, E.. - In: ANNALS OF NUCLEAR ENERGY. - ISSN 0306-4549. - ELETTRONICO. - 208:(2024). [10.1016/j.anucene.2024.110791]

Global Sensitivity Analysis for Segmented Inverse Uncertainty Quantification in the Safety Analysis of Nuclear Power Plants

Pedroni N.;
2024

Abstract

Within the Best Estimate Plus Uncertainty framework for the safety analysis of Nuclear Power Plants, the quantification of the uncertainties affecting the Thermal-Hydraulics (T-H) codes used is crucial. For this, Inverse Uncertainty Quantification (IUQ) methodologies are being developed for determining the probability density functions of relevant T-H codes input parameters, based on experimental data from Separate Effect Tests (SETs) experimental facilities. In practice, IUQ is challenged by the large range of variability of the experimental data in terms of Initial and Boundary Conditions (ICs & BCs), because the experimental campaigns are designed to cover the widest possible domain of conditions with the smallest number of experiments, so that same or similar ICs and BCs are seldomly repeated. To address this issue, we propose to use global sensitivity analysis, to tailor the IUQ on specific sub-regions described by segmented ICs & BCs domains. The methodology proposed is exemplified on two SETs, namely Sozzi-Sutherland and Super Moby Dick, whose experimental databases have been made available in the ATRIUM (Application Tests for Realization of Inverse Uncertainty quantification and validation Methodologies in thermal hydraulics) project promoted by the OECD/NEA/CSNI. The results obtained are superior to those of traditional IUQ methodologies for models highly sensitive to ICs & BCs.
File in questo prodotto:
File Dimensione Formato  
Annals_2024_Final_Global+SA+Segmented+IUQ+Safety+Analysis+NPPs_compressed.pdf

accesso aperto

Tipologia: 2a Post-print versione editoriale / Version of Record
Licenza: Creative commons
Dimensione 1.45 MB
Formato Adobe PDF
1.45 MB Adobe PDF Visualizza/Apri
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11583/2993658