Humic-like substances (HLS) extracted from urban wastes have been tested as auxiliaries for the photo-Fenton removal of thiabendazole (TBZ) under simulated sunlight. Experimental design methodology based on Doehlert matrices was employed to check the effects of hydrogen peroxide concentration, HLS amount as well as TBZ loading; this last parameter was studied in the range 25–100 mg/L, to include values below and above the limit of solubility at pH = 5. Very satisfactory results were reached when TBZ was above solubility if HLS and H2O2 amounts were high. This could be attributed to an interaction of HLS-TBZ that enhances the solubility of the pollutant. Additional evidence supporting the latter interaction was obtained by fluorescence measurements (excitation emission matrices) and parallel factor analysis (PARAFAC).

Humic like substances for the treatment of scarcely soluble pollutants by mild photo-Fenton process / Caram, B.; Garcia-Ballesteros, S.; Santos-Juanes, L.; Arques, A.; Garcia-Einschlag, F. S.. - In: CHEMOSPHERE. - ISSN 0045-6535. - 198:(2018), pp. 139-146. [10.1016/j.chemosphere.2018.01.074]

Humic like substances for the treatment of scarcely soluble pollutants by mild photo-Fenton process

Garcia-Ballesteros S.;
2018

Abstract

Humic-like substances (HLS) extracted from urban wastes have been tested as auxiliaries for the photo-Fenton removal of thiabendazole (TBZ) under simulated sunlight. Experimental design methodology based on Doehlert matrices was employed to check the effects of hydrogen peroxide concentration, HLS amount as well as TBZ loading; this last parameter was studied in the range 25–100 mg/L, to include values below and above the limit of solubility at pH = 5. Very satisfactory results were reached when TBZ was above solubility if HLS and H2O2 amounts were high. This could be attributed to an interaction of HLS-TBZ that enhances the solubility of the pollutant. Additional evidence supporting the latter interaction was obtained by fluorescence measurements (excitation emission matrices) and parallel factor analysis (PARAFAC).
File in questo prodotto:
File Dimensione Formato  
1-s2.0-S0045653518300821-main.pdf

accesso riservato

Tipologia: 2a Post-print versione editoriale / Version of Record
Licenza: Non Pubblico - Accesso privato/ristretto
Dimensione 1.33 MB
Formato Adobe PDF
1.33 MB Adobe PDF   Visualizza/Apri   Richiedi una copia
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11583/2992202