The paper analyses the impact of different simplification approaches for model verification purposes considering a reference demo case of a municipality school located in Torre Pellice (Italy), which has been monitored with room detail since April 2021. The target variable of the calibration process is the indoor air temperature: firstly, results validity is checked on an unoccupied free-running period; secondly, occupied standard behaviours and adapted to real-use ones are adopted to test the simplification choices impact on indoor thermal comfort indicators (e.g. the Adaptive Comfort Model). Several model simplification actions on both building-level construction and zoning approaches are considered. Results of this demo case demonstrate the usability of simplified models, which can be adopted instead of more detailed and time-consuming full models for performance gap detections and other analyses.

Impact of different thermal zone data simplification for model calibration on monitored-simulated performance gaps / Chiesa, G; Fasano, F; Grasso, P. - In: JOURNAL OF PHYSICS. CONFERENCE SERIES. - ISSN 1742-6588. - ELETTRONICO. - 2600:9(2023). [10.1088/1742-6596/2600/9/092022]

Impact of different thermal zone data simplification for model calibration on monitored-simulated performance gaps

Chiesa, G;
2023

Abstract

The paper analyses the impact of different simplification approaches for model verification purposes considering a reference demo case of a municipality school located in Torre Pellice (Italy), which has been monitored with room detail since April 2021. The target variable of the calibration process is the indoor air temperature: firstly, results validity is checked on an unoccupied free-running period; secondly, occupied standard behaviours and adapted to real-use ones are adopted to test the simplification choices impact on indoor thermal comfort indicators (e.g. the Adaptive Comfort Model). Several model simplification actions on both building-level construction and zoning approaches are considered. Results of this demo case demonstrate the usability of simplified models, which can be adopted instead of more detailed and time-consuming full models for performance gap detections and other analyses.
File in questo prodotto:
File Dimensione Formato  
Chiesa_2023_J._Phys.__Conf._Ser._2600_092022 (2).pdf

accesso aperto

Tipologia: 2a Post-print versione editoriale / Version of Record
Licenza: Creative commons
Dimensione 967.08 kB
Formato Adobe PDF
967.08 kB Adobe PDF Visualizza/Apri
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11583/2988176