The analysis of the radiation damage of imaging systems is based on all different types-of aiialoiue/digital cameras with uncooled as well as actively cooled image sensors in the VIS/NIR/MWIR spectral ranges. The Monte Carlo N-Particle (MCNP) code has been used to determine the neutron fluence at different camera locations in JET. An explicit link between the sensor damage and the neutron fluence has been observed. Sensors show an increased dark-current and increased numbers of hot-pixels. Uncooled cameras must be replaced once per year after exposure to a neutron fluence of similar to 1.9-3.2 x 10(12)neutrons/cm(2). Such levels of fluence will be reached after approximate to 14-22 ELMy H-mode pulses during the future D-T campaign. Furthermore, dynamical noise seen as a random pattern of bright pixels was observed in the presence of hard radiation (neutrons and gammas). Failure of the digital electronics inside the cameras as well as of industrial controllers is observed beyond a neutron fluence of about similar to 4 x 10(9) neutrons/cm(2). The impact of hard radiation on the different types of electronics and possible application of cameras during future D-T campaign is discussed. (C) 2017 The Author(s). Published by Elsevier B.V.
Response of the imaging cameras to hard radiation during JET operation / Huber, Alexander; Sergienko, Gennady; Kinna, David; Huber, Valentina; Milocco, Alberto; Mercadier, Laurent; Balboa, Itziar; Conroy, Sean; Cramp, Simon; Kiptily, Vasili; Kruezi, Uron; Lambertz, Horst Toni; Linsmeier, Christian; Matthews, Guy; Popovichev, Sergey; Mertens, Philippe; Silburn, Scott; Subba, Fabio; Zastrow, Klaus-Dieter. - In: FUSION ENGINEERING AND DESIGN. - ISSN 0920-3796. - 123:(2017), pp. 669-673. [10.1016/j.fusengdes.2017.03.167]
Response of the imaging cameras to hard radiation during JET operation
Subba, Fabio;
2017
Abstract
The analysis of the radiation damage of imaging systems is based on all different types-of aiialoiue/digital cameras with uncooled as well as actively cooled image sensors in the VIS/NIR/MWIR spectral ranges. The Monte Carlo N-Particle (MCNP) code has been used to determine the neutron fluence at different camera locations in JET. An explicit link between the sensor damage and the neutron fluence has been observed. Sensors show an increased dark-current and increased numbers of hot-pixels. Uncooled cameras must be replaced once per year after exposure to a neutron fluence of similar to 1.9-3.2 x 10(12)neutrons/cm(2). Such levels of fluence will be reached after approximate to 14-22 ELMy H-mode pulses during the future D-T campaign. Furthermore, dynamical noise seen as a random pattern of bright pixels was observed in the presence of hard radiation (neutrons and gammas). Failure of the digital electronics inside the cameras as well as of industrial controllers is observed beyond a neutron fluence of about similar to 4 x 10(9) neutrons/cm(2). The impact of hard radiation on the different types of electronics and possible application of cameras during future D-T campaign is discussed. (C) 2017 The Author(s). Published by Elsevier B.V.File | Dimensione | Formato | |
---|---|---|---|
1-s2.0-S0920379617303915-main.pdf
accesso riservato
Tipologia:
2a Post-print versione editoriale / Version of Record
Licenza:
Non Pubblico - Accesso privato/ristretto
Dimensione
1.42 MB
Formato
Adobe PDF
|
1.42 MB | Adobe PDF | Visualizza/Apri Richiedi una copia |
Pubblicazioni consigliate
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.
https://hdl.handle.net/11583/2986888