Objectives: The aim of this study was to clinically evaluate the accuracy of a digital axiographic recording system in tracing the sagittal condylar inclination. Methods: An axiographic examination that records the sagittal condylar path during protrusive/retrusive movement was performed on ten patients. Each subject was registered five different times by two different systems: 1) the Cadiax Gamma Diagnostic 4 computerized system as the control; 2) the Zebris Jaw Motion Analyser+ Optic System as the tested digital axiographic recording system. The records obtained allow to calculate the kinematic terminal transverse horizontal axis and the sagittal condylar inclination (SCI) at 3 and 5 mm along the pro-retrusive path. A linear mixed model was used to analyze if there was a statistically significant difference between the two systems. Results: The mean left SCI value recorded by Zebris system were 49.81 ± 10.64° at 3 mm, 48.10 ± 11.04° at 5 mm, while the values recorded by Gamma system were 55.16° at 3 mm, 52.18° at 5 mm. The mean right SCI value recorded by Zebris system were 54.53 ± 10.26° at 3 mm, 51.85 ± 8.55° at 5 mm, while the values recorded by Gamma system were 49.68° at 3 mm, 48.23° at 5 mm. Linear mixed model showed no significant statistical difference between the two systems. Conclusions: Based on preliminary results, the Zebris Jaw Motion Analyzer+ Optic System demonstrates comparable accuracy to the Cadiax Gamma Diagnostic 4 when measuring sagittal condylar inclination. Clinical significance: The digital axiographic recording system enables to evaluate sagittal condylar inclination and to adjust virtual articulators in a digital workflow.

Preliminary clinical study of the accuracy of a digital axiographic recording system for the assessment of sagittal condylar inclination / Lepidi, L.; Grande, F.; Baldassarre, G.; Suriano, C.; Li, J.; Catapano, S.. - In: JOURNAL OF DENTISTRY. - ISSN 0300-5712. - 135:(2023), p. 104583. [10.1016/j.jdent.2023.104583]

Preliminary clinical study of the accuracy of a digital axiographic recording system for the assessment of sagittal condylar inclination

Grande F.;
2023

Abstract

Objectives: The aim of this study was to clinically evaluate the accuracy of a digital axiographic recording system in tracing the sagittal condylar inclination. Methods: An axiographic examination that records the sagittal condylar path during protrusive/retrusive movement was performed on ten patients. Each subject was registered five different times by two different systems: 1) the Cadiax Gamma Diagnostic 4 computerized system as the control; 2) the Zebris Jaw Motion Analyser+ Optic System as the tested digital axiographic recording system. The records obtained allow to calculate the kinematic terminal transverse horizontal axis and the sagittal condylar inclination (SCI) at 3 and 5 mm along the pro-retrusive path. A linear mixed model was used to analyze if there was a statistically significant difference between the two systems. Results: The mean left SCI value recorded by Zebris system were 49.81 ± 10.64° at 3 mm, 48.10 ± 11.04° at 5 mm, while the values recorded by Gamma system were 55.16° at 3 mm, 52.18° at 5 mm. The mean right SCI value recorded by Zebris system were 54.53 ± 10.26° at 3 mm, 51.85 ± 8.55° at 5 mm, while the values recorded by Gamma system were 49.68° at 3 mm, 48.23° at 5 mm. Linear mixed model showed no significant statistical difference between the two systems. Conclusions: Based on preliminary results, the Zebris Jaw Motion Analyzer+ Optic System demonstrates comparable accuracy to the Cadiax Gamma Diagnostic 4 when measuring sagittal condylar inclination. Clinical significance: The digital axiographic recording system enables to evaluate sagittal condylar inclination and to adjust virtual articulators in a digital workflow.
File in questo prodotto:
File Dimensione Formato  
Preliminary clinical study of the accuracy of a digital axiographic recording system for the assessment of sagittal condylar inclination.pdf

non disponibili

Tipologia: 2a Post-print versione editoriale / Version of Record
Licenza: Non Pubblico - Accesso privato/ristretto
Dimensione 9.22 MB
Formato Adobe PDF
9.22 MB Adobe PDF   Visualizza/Apri   Richiedi una copia
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11583/2983336