Objective: Crosstalk in surface electromyogram (EMG) is an important open problem and the common strategy of reducing it through spatial filters needs improvements. Methods: We evaluated experimentally the optimal spatio-temporal filter (OSTF), i.e., a recent approach that adapts to the subject, filtering different EMG channels both in time and space to emphasize the signal of a target muscle discarding that of adjacent ones. EMGs were recorded by a high-density recording system from pronator teres (target muscle) and flexor carpi radialis (crosstalk muscle) of 8 healthy subjects. OSTF was tested in different conditions, considering one channel per muscle (either single or double differential, SD and DD, respectively), changing the selectivity of detection (small electrodes close to each other, or large ones with higher inter-electrode distance), the force applied by the muscles (whose EMGs were summed to simulate different levels of crosstalk), and the duration of the signal to train the method. Results: OSTF was less affected by crosstalk than SD and DD filters. Statistically significant improvements were obtained in reducing the crosstalk-induced variations: for example, considering small electrodes, we obtained a percentage error of 157.30±57.11 % and 38.54±10.47 % (mean±std) in the estimation of the average rectified value (ARV), and an error of 23.57±3.92 % and 8.31±0.88 % in the estimation of the median frequency (MDF), for SD and OSTF, respectively. Conclusion: The OSTF can be applied in real-time, is easy to use, and is feasible even when using only few detection channels, as is customary in many applications.

Reduction of Crosstalk in the Electromyogram: Experimental Validation of the Optimal Spatio-Temporal Filter / Raggi, Matteo; Boccia, Gennaro; Mesin, Luca. - In: IEEE ACCESS. - ISSN 2169-3536. - ELETTRONICO. - 11:(2023), pp. 112075-112084. [10.1109/ACCESS.2023.3323209]

Reduction of Crosstalk in the Electromyogram: Experimental Validation of the Optimal Spatio-Temporal Filter

Raggi, Matteo;Boccia, Gennaro;Mesin, Luca
2023

Abstract

Objective: Crosstalk in surface electromyogram (EMG) is an important open problem and the common strategy of reducing it through spatial filters needs improvements. Methods: We evaluated experimentally the optimal spatio-temporal filter (OSTF), i.e., a recent approach that adapts to the subject, filtering different EMG channels both in time and space to emphasize the signal of a target muscle discarding that of adjacent ones. EMGs were recorded by a high-density recording system from pronator teres (target muscle) and flexor carpi radialis (crosstalk muscle) of 8 healthy subjects. OSTF was tested in different conditions, considering one channel per muscle (either single or double differential, SD and DD, respectively), changing the selectivity of detection (small electrodes close to each other, or large ones with higher inter-electrode distance), the force applied by the muscles (whose EMGs were summed to simulate different levels of crosstalk), and the duration of the signal to train the method. Results: OSTF was less affected by crosstalk than SD and DD filters. Statistically significant improvements were obtained in reducing the crosstalk-induced variations: for example, considering small electrodes, we obtained a percentage error of 157.30±57.11 % and 38.54±10.47 % (mean±std) in the estimation of the average rectified value (ARV), and an error of 23.57±3.92 % and 8.31±0.88 % in the estimation of the median frequency (MDF), for SD and OSTF, respectively. Conclusion: The OSTF can be applied in real-time, is easy to use, and is feasible even when using only few detection channels, as is customary in many applications.
2023
File in questo prodotto:
File Dimensione Formato  
Reduction_of_Crosstalk_in_the_Electromyogram_Experimental_Validation_of_the_Optimal_Spatio-Temporal_Filter.pdf

accesso aperto

Descrizione: Versione editoriale dell'articolo
Tipologia: 2a Post-print versione editoriale / Version of Record
Licenza: Creative commons
Dimensione 2.03 MB
Formato Adobe PDF
2.03 MB Adobe PDF Visualizza/Apri
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11583/2983124