The Atrial Flow Regulator (AFR) is a self-expandable double-disk device with a central fenestration, intended to maintain a calibrated communication across the interatrial septum. Only case reports and small case series have been published about its use in the pediatric and congenital heart disease (CHD) population. We described AFR implantation in three congenital patients with different anatomies and indications. In the first case, the AFR was deployed to create a stable fenestration in a Fontan conduit, while in the second, it was used to reduce a Fontan fenestration. In the third case, we implanted an AFR to decompress the left atrium of an adolescent with complex CHD in natural history, with complete mixing, ductal-dependent systemic circulation and combined pulmonary hypertension. This case series demonstrates the great potential of the AFR device in the CHD field, showing versatility, efficacy, and safety in establishing a calibrated and stable shunt, with promising hemodynamic and symptomatic benefits.
Versatility of Atrial Flow Regulator Device in Congenital Heart Disease: A Case Series / Piccinelli, Enrico; Testa, Alberto; Butera, Gianfranco. - In: PEDIATRIC CARDIOLOGY. - ISSN 0172-0643. - (2024). [10.1007/s00246-023-03123-y]
Versatility of Atrial Flow Regulator Device in Congenital Heart Disease: A Case Series
Piccinelli, Enrico;
2024
Abstract
The Atrial Flow Regulator (AFR) is a self-expandable double-disk device with a central fenestration, intended to maintain a calibrated communication across the interatrial septum. Only case reports and small case series have been published about its use in the pediatric and congenital heart disease (CHD) population. We described AFR implantation in three congenital patients with different anatomies and indications. In the first case, the AFR was deployed to create a stable fenestration in a Fontan conduit, while in the second, it was used to reduce a Fontan fenestration. In the third case, we implanted an AFR to decompress the left atrium of an adolescent with complex CHD in natural history, with complete mixing, ductal-dependent systemic circulation and combined pulmonary hypertension. This case series demonstrates the great potential of the AFR device in the CHD field, showing versatility, efficacy, and safety in establishing a calibrated and stable shunt, with promising hemodynamic and symptomatic benefits.| File | Dimensione | Formato | |
|---|---|---|---|
| s00246-023-03123-y.pdf accesso riservato 
											Tipologia:
											2a Post-print versione editoriale / Version of Record
										 
											Licenza:
											
											
												Non Pubblico - Accesso privato/ristretto
												
												
												
											
										 
										Dimensione
										1.23 MB
									 
										Formato
										Adobe PDF
									 | 1.23 MB | Adobe PDF | Visualizza/Apri Richiedi una copia | 
Pubblicazioni consigliate
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.
https://hdl.handle.net/11583/2982602
			
		
	
	
	
			      	