The decontamination of stainless-steel surfaces in Light Water Reactors components, that may suffer from nuclear activation and contamination, is still a topic that deserves research and development studies. In this paper, the HP-CORD-UV chemical method for the removal of thin surface layers from AISI 304 stainless steel samples is addressed, considering multiple cycles of oxidation and cleaning. A procedure for the optimization of the oxidation phase considering in particular the pH of the solution, the ([KMnO4]/[H+] ratio), and the immersion time (oxidation time), was developed and is here presented. The experimental results show that 10 oxidation cycles at pH 3, [MnO4-] = [H+], for 2 h, followed by 30 min of cleaning in oxalic acid, allowed to reach a thickness of dissolved metal of about 3–4 μm. Despite the intrinsic localised morphology of the corrosion attack on AISI 304 sample surface, scanning electron microscopy showed good reproducibility of the process.

Optimization for the HP-CORD UV chemical decontamination process for AISI 304 stainless steel / Corrado, M.; Cao, S.; Grassini, S.; Iannucci, L.; Savoldi, L.. - In: NUCLEAR ENGINEERING AND DESIGN. - ISSN 0029-5493. - ELETTRONICO. - 414:(2023), pp. 1-9. [10.1016/j.nucengdes.2023.112550]

Optimization for the HP-CORD UV chemical decontamination process for AISI 304 stainless steel

Corrado M.;Cao S.;Grassini S.;Iannucci L.;Savoldi L.
2023

Abstract

The decontamination of stainless-steel surfaces in Light Water Reactors components, that may suffer from nuclear activation and contamination, is still a topic that deserves research and development studies. In this paper, the HP-CORD-UV chemical method for the removal of thin surface layers from AISI 304 stainless steel samples is addressed, considering multiple cycles of oxidation and cleaning. A procedure for the optimization of the oxidation phase considering in particular the pH of the solution, the ([KMnO4]/[H+] ratio), and the immersion time (oxidation time), was developed and is here presented. The experimental results show that 10 oxidation cycles at pH 3, [MnO4-] = [H+], for 2 h, followed by 30 min of cleaning in oxalic acid, allowed to reach a thickness of dissolved metal of about 3–4 μm. Despite the intrinsic localised morphology of the corrosion attack on AISI 304 sample surface, scanning electron microscopy showed good reproducibility of the process.
File in questo prodotto:
File Dimensione Formato  
1-s2.0-S0029549323003990-main-2_compressed.pdf

accesso aperto

Tipologia: 2a Post-print versione editoriale / Version of Record
Licenza: Creative commons
Dimensione 2.02 MB
Formato Adobe PDF
2.02 MB Adobe PDF Visualizza/Apri
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11583/2981370