Chromium (VI) water contamination still represents a great risk to human health. Consequently, the need for unconventional adsorbents with remarkable sorption abilities is dramatically increasing. Hence, in this study, nickel hydroxide nanoplates (nNiHs) were developed to achieve rapid , significant Cr(VI) removal from aqueous solutions. nNiHs showed an average particle size and crystallite size of 36.8 nm and 8.68 nm, respectively. Different reaction parameters were investigated, including nNiHs dosage, pH, reaction temperature, initial Cr(VI) concentration , co-existing anions. nNiHs could efficiently remove 20 mg/L Cr(VI) concentration over a wide pH and temperature range(s) (5.0-9.0) and (25- 75 degrees C), respectively. Pseudo 2nd order kinetic model and Freundlich isotherm model were the best to fit experimental data. A maximum Cr(VI) sorption capacity of 71.25 mg/g was achieved at the optimal reaction conditions (pH 5.0, temperature 25 degrees C, and dosage 2 g/L), comparable to the previously reported values. The governing Cr(VI) removal mechanism by nNiHs involved the high dominance of electrostatic adsorption and the low dominance of co-precipitation. The high sorption potential of the nNiHs and the high affinity of the aqueous Cr(VI) species, enabled the proposed adsorbent to yield an efficient perfor-mance in binary environmental systems. (c) 2022 Elsevier B.V. All rights reserved.

Rapid and efficient chromium (VI) removal from aqueous solutions using nickel hydroxide nanoplates (nNiHs) / Maamoun, Ibrahim; Bensaida, Khaoula; Eljamal, Ramadan; Falyouna, Omar; Tanaka, Kazuya; Tosco, TIZIANA ANNA ELISABETTA; Sugihara, Yuji; Eljamal, Osama. - In: JOURNAL OF MOLECULAR LIQUIDS. - ISSN 0167-7322. - STAMPA. - 358:(2022), pp. 1-13. [10.1016/j.molliq.2022.119216]

Rapid and efficient chromium (VI) removal from aqueous solutions using nickel hydroxide nanoplates (nNiHs)

Tiziana Tosco;
2022

Abstract

Chromium (VI) water contamination still represents a great risk to human health. Consequently, the need for unconventional adsorbents with remarkable sorption abilities is dramatically increasing. Hence, in this study, nickel hydroxide nanoplates (nNiHs) were developed to achieve rapid , significant Cr(VI) removal from aqueous solutions. nNiHs showed an average particle size and crystallite size of 36.8 nm and 8.68 nm, respectively. Different reaction parameters were investigated, including nNiHs dosage, pH, reaction temperature, initial Cr(VI) concentration , co-existing anions. nNiHs could efficiently remove 20 mg/L Cr(VI) concentration over a wide pH and temperature range(s) (5.0-9.0) and (25- 75 degrees C), respectively. Pseudo 2nd order kinetic model and Freundlich isotherm model were the best to fit experimental data. A maximum Cr(VI) sorption capacity of 71.25 mg/g was achieved at the optimal reaction conditions (pH 5.0, temperature 25 degrees C, and dosage 2 g/L), comparable to the previously reported values. The governing Cr(VI) removal mechanism by nNiHs involved the high dominance of electrostatic adsorption and the low dominance of co-precipitation. The high sorption potential of the nNiHs and the high affinity of the aqueous Cr(VI) species, enabled the proposed adsorbent to yield an efficient perfor-mance in binary environmental systems. (c) 2022 Elsevier B.V. All rights reserved.
File in questo prodotto:
File Dimensione Formato  
1-s2.0-S0167732222007541-main.pdf

accesso riservato

Descrizione: Full text
Tipologia: 2a Post-print versione editoriale / Version of Record
Licenza: Non Pubblico - Accesso privato/ristretto
Dimensione 2.05 MB
Formato Adobe PDF
2.05 MB Adobe PDF   Visualizza/Apri   Richiedi una copia
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11583/2979854