We sought to test the accuracy of 24-hours ambulatory blood pressure (BP) monitoring (ABPM) for the detection of orthostatic hypotension (OH) in Parkinson's disease (PD). A total of 113 patients referred for autonomic testing between January 2015 and June 2017 underwent ABPM and office BP measurements in supine and standing positions. The study population consisted of 81 males and 32 females with PD duration of 6.5 +/- 4.1 years and Hoehn and Yahr staging of 1 (13.3%), 1.5 (20.4%), 2 (27.4%), 2.5 (23.9%), 3 (13.3%), and 4 (1.8%). Motor fluctuations were present in 44% of patients. The data from office BP recordings were compared to selected ABPM parameters, and the results showed an association between OH and (a) ABPM-detected hypotensive episodes (Hypo-ep) and (b) ABPM-detected awakening hypotension (Hypo-aw). Having 2 or more Hypo-ep episodes <= 15 mmHg (systolic) compared to average 24-h systolic BP (Hypo-ep(Delta 15/24h)) yielded 75% diagnostic accuracy for OH, while the presence of at least one Hypo-ep(Delta 15/24h) within 90 min after getting up (Hypo-aw(Delta 15/24h)) yielded 93% specificity for OH. A diagnostic accuracy of 87.6% was achieved when including daytime and nighttime ABPM values, weighted BP variability, systolic and diastolic BP loads, nocturnal dipping, and postprandial hypotension in a computerized prediction algorithm. In conclusion, our findings suggest that selected ABPM parameters, such as the number of hypotensive episodes and the presence of awakening hypotension, may be used to screen patients for OH, while using a computerized prediction algorithm that includes all ABPM parameters provides the greatest diagnostic accuracy.

Detection of orthostatic hypotension with ambulatory blood pressure monitoring in parkinson's disease / Vallelonga, Fabrizio; Romagnolo, Alberto; Merola, Aristide; Sobrero, Gabriele; Di Stefano, Cristina; Milazzo, Valeria; Burrello, Jacopo; Burrello, Alessio; Zibetti, Maurizio; Milan, Alberto; Veglio, Franco; Maule, Simona. - In: HYPERTENSION RESEARCH. - ISSN 0916-9636. - 42:(2019), pp. 1552-1560. [10.1038/s41440-019-0267-x]

Detection of orthostatic hypotension with ambulatory blood pressure monitoring in parkinson's disease

Di Stefano, Cristina;Milazzo, Valeria;Burrello, Alessio;Milan, Alberto;
2019

Abstract

We sought to test the accuracy of 24-hours ambulatory blood pressure (BP) monitoring (ABPM) for the detection of orthostatic hypotension (OH) in Parkinson's disease (PD). A total of 113 patients referred for autonomic testing between January 2015 and June 2017 underwent ABPM and office BP measurements in supine and standing positions. The study population consisted of 81 males and 32 females with PD duration of 6.5 +/- 4.1 years and Hoehn and Yahr staging of 1 (13.3%), 1.5 (20.4%), 2 (27.4%), 2.5 (23.9%), 3 (13.3%), and 4 (1.8%). Motor fluctuations were present in 44% of patients. The data from office BP recordings were compared to selected ABPM parameters, and the results showed an association between OH and (a) ABPM-detected hypotensive episodes (Hypo-ep) and (b) ABPM-detected awakening hypotension (Hypo-aw). Having 2 or more Hypo-ep episodes <= 15 mmHg (systolic) compared to average 24-h systolic BP (Hypo-ep(Delta 15/24h)) yielded 75% diagnostic accuracy for OH, while the presence of at least one Hypo-ep(Delta 15/24h) within 90 min after getting up (Hypo-aw(Delta 15/24h)) yielded 93% specificity for OH. A diagnostic accuracy of 87.6% was achieved when including daytime and nighttime ABPM values, weighted BP variability, systolic and diastolic BP loads, nocturnal dipping, and postprandial hypotension in a computerized prediction algorithm. In conclusion, our findings suggest that selected ABPM parameters, such as the number of hypotensive episodes and the presence of awakening hypotension, may be used to screen patients for OH, while using a computerized prediction algorithm that includes all ABPM parameters provides the greatest diagnostic accuracy.
File in questo prodotto:
File Dimensione Formato  
s41440-019-0267-x.pdf

accesso riservato

Tipologia: 2a Post-print versione editoriale / Version of Record
Licenza: Non Pubblico - Accesso privato/ristretto
Dimensione 790.45 kB
Formato Adobe PDF
790.45 kB Adobe PDF   Visualizza/Apri   Richiedi una copia
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11583/2978499