The deployment of artificial structures in streambeds has been proposed as a way to enhance hyporheic exchange, and numerical models can be used to quantify their effects. In this study, combinations of different structures—that is, boxes, steps and a new type of subsurface structure (L-shaped structure)—were considered to evaluate their potential applicability on river restoration. Flow-3D and COMSOL were applied to simulate surface and subsurface flow, respectively. The performance of the structures was evaluated on the basis of hyporheic flow and residence time distributions. For the structure sizes here considered, results showed for steps (single step, combination of two steps) and L-shaped structures (single L-shaped structure, combination of two L-shaped structures) most hyporheic flowpaths return to the stream after 5 and 2.5 hr, respectively. Instead, shorter residence times (<0.25 hr) were found for boxes (single box, combination of two boxes). For combinations of steps and permeable boxes, the values of hyporheic flow per unit width are higher (0.35 and 0.3 m2/hr, respectively) than for the combination of L-shaped (0.06 m 2/hr). As a result, the combinations of steps and boxes are more effective in increasing hyporheic flow. However, when subsurface structures are combined with steps the resulting hyporheic exchange is dominated by the steps. Therefore, the combined use of in-stream and subsurface structures separately may increase their benefits for hyporheic exchange, but when steps are the other subsurface structures provide minor advantages.

Effect of Combined Subsurface Structures and Steps on Hyporheic Exchange / Tajari, M.; Omid, M. H.; Dehghani, A. A.; Ghameshlou, A. N.; Boano, F.. - In: WATER RESOURCES RESEARCH. - ISSN 0043-1397. - 59:5(2023). [10.1029/2022WR033991]

Effect of Combined Subsurface Structures and Steps on Hyporheic Exchange

F. Boano
2023

Abstract

The deployment of artificial structures in streambeds has been proposed as a way to enhance hyporheic exchange, and numerical models can be used to quantify their effects. In this study, combinations of different structures—that is, boxes, steps and a new type of subsurface structure (L-shaped structure)—were considered to evaluate their potential applicability on river restoration. Flow-3D and COMSOL were applied to simulate surface and subsurface flow, respectively. The performance of the structures was evaluated on the basis of hyporheic flow and residence time distributions. For the structure sizes here considered, results showed for steps (single step, combination of two steps) and L-shaped structures (single L-shaped structure, combination of two L-shaped structures) most hyporheic flowpaths return to the stream after 5 and 2.5 hr, respectively. Instead, shorter residence times (<0.25 hr) were found for boxes (single box, combination of two boxes). For combinations of steps and permeable boxes, the values of hyporheic flow per unit width are higher (0.35 and 0.3 m2/hr, respectively) than for the combination of L-shaped (0.06 m 2/hr). As a result, the combinations of steps and boxes are more effective in increasing hyporheic flow. However, when subsurface structures are combined with steps the resulting hyporheic exchange is dominated by the steps. Therefore, the combined use of in-stream and subsurface structures separately may increase their benefits for hyporheic exchange, but when steps are the other subsurface structures provide minor advantages.
File in questo prodotto:
File Dimensione Formato  
Water Resources Research - 2023 - Tajari - Effect of Combined Subsurface Structures and Steps on Hyporheic Exchange.pdf

accesso aperto

Tipologia: 2a Post-print versione editoriale / Version of Record
Licenza: Creative commons
Dimensione 5.11 MB
Formato Adobe PDF
5.11 MB Adobe PDF Visualizza/Apri
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11583/2978457