The AC loss tests on the first ITER Central Solenoid Module (CSM) have been modelled and compared to the test results. The model has been implemented in the 4C code, a thermal-hydraulic modelling tool which includes the CSM winding pack and the cryogenic circuit of the test facility. Two modes of operation of the circuit have been analyzed: the nominal and the “isolation” mode, i.e., when the cryogenic circuit valves are operated to isolate the coil during the current dumps. The computed mass flow rate, pressure and coil outlet temperature at different locations have been compared with the measurements, showing a very good agreement in both modes of operation of the circuit. The validated model helped in the interpretation of the experimental results, such as the backflow at the coil inlet -which cannot be measured- or the non-monotonic outlet temperature evolution following the current dump. Furthermore, the code was used to qualify the isochoric method for the quantification of the deposited energy due to AC losses, as it was the only method applicable in case of current dumps from high current.
Validation of the 4C Code on the AC Loss Tests of a Full-Scale ITER Coil / Zappatore, Andrea; Bonifetto, Roberto; Martovetsky, Nicolai; Zanino, Roberto. - In: IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY. - ISSN 1051-8223. - ELETTRONICO. - 33:5(2023), pp. 1-5. [10.1109/TASC.2023.3263136]
Validation of the 4C Code on the AC Loss Tests of a Full-Scale ITER Coil
Zappatore, Andrea;Bonifetto, Roberto;Zanino, Roberto
2023
Abstract
The AC loss tests on the first ITER Central Solenoid Module (CSM) have been modelled and compared to the test results. The model has been implemented in the 4C code, a thermal-hydraulic modelling tool which includes the CSM winding pack and the cryogenic circuit of the test facility. Two modes of operation of the circuit have been analyzed: the nominal and the “isolation” mode, i.e., when the cryogenic circuit valves are operated to isolate the coil during the current dumps. The computed mass flow rate, pressure and coil outlet temperature at different locations have been compared with the measurements, showing a very good agreement in both modes of operation of the circuit. The validated model helped in the interpretation of the experimental results, such as the backflow at the coil inlet -which cannot be measured- or the non-monotonic outlet temperature evolution following the current dump. Furthermore, the code was used to qualify the isochoric method for the quantification of the deposited energy due to AC losses, as it was the only method applicable in case of current dumps from high current.File | Dimensione | Formato | |
---|---|---|---|
Validation_of_the_4C_Code_on_the_AC_Loss_Tests_of_a_Full-Scale_ITER_Coil.pdf
accesso aperto
Tipologia:
2a Post-print versione editoriale / Version of Record
Licenza:
Creative commons
Dimensione
1.58 MB
Formato
Adobe PDF
|
1.58 MB | Adobe PDF | Visualizza/Apri |
Pubblicazioni consigliate
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.
https://hdl.handle.net/11583/2978283