The three-phase symmetric short-circuit is a reference fault condition for the qualification of a newly designed permanent magnet (PM) synchronous machine against the risk of irreversible demagnetization. To date, the accurate determination of the peak transient short-circuit current condition requires coupled circuital and transient Finite Element Analysis (FEA) to properly account for magnetic saturation, and several simulations to determine the worst-case pre-fault conditions. This work presents a method for the fast evaluation of the transient short-circuit current of a PM synchronous machine by manipulation of extended flux linkage maps, obtained with magnetostatic FEA or experimental measures. Besides providing a fast and accessible computational tool, the flux-map based method gives insights into the effect of pre-fault conditions, showing that the higher the pre-fault torque and thus flux amplitude, the higher the transient peak current after a fault. Moreover, the paper shows that braking is a more severe pre-fault condition. Finally, the hyper-worst-case short circuit current is also defined as the magnetic property of the machine under test and computed by means of quick FEA iterations without the need for pre-determined flux-linkage maps. The proposed methods are validated against transient FEA using a commercial software and verified experimentally on a commercial motor for traction applications.

Fast Determination of Transient Short-Circuit Current of PM Synchronous Machines Via Magnetostatic Flux Maps / Ferrari, Simone; Dilevrano, Gaetano; Ragazzo, Paolo; Pescetto, Paolo; Pellegrino, Gianmario. - In: IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS. - ISSN 0093-9994. - STAMPA. - (2023), pp. 1-10. [10.1109/TIA.2023.3265952]

Fast Determination of Transient Short-Circuit Current of PM Synchronous Machines Via Magnetostatic Flux Maps

Simone Ferrari;Gaetano Dilevrano;Paolo Ragazzo;Paolo Pescetto;Gianmario Pellegrino
2023

Abstract

The three-phase symmetric short-circuit is a reference fault condition for the qualification of a newly designed permanent magnet (PM) synchronous machine against the risk of irreversible demagnetization. To date, the accurate determination of the peak transient short-circuit current condition requires coupled circuital and transient Finite Element Analysis (FEA) to properly account for magnetic saturation, and several simulations to determine the worst-case pre-fault conditions. This work presents a method for the fast evaluation of the transient short-circuit current of a PM synchronous machine by manipulation of extended flux linkage maps, obtained with magnetostatic FEA or experimental measures. Besides providing a fast and accessible computational tool, the flux-map based method gives insights into the effect of pre-fault conditions, showing that the higher the pre-fault torque and thus flux amplitude, the higher the transient peak current after a fault. Moreover, the paper shows that braking is a more severe pre-fault condition. Finally, the hyper-worst-case short circuit current is also defined as the magnetic property of the machine under test and computed by means of quick FEA iterations without the need for pre-determined flux-linkage maps. The proposed methods are validated against transient FEA using a commercial software and verified experimentally on a commercial motor for traction applications.
File in questo prodotto:
File Dimensione Formato  
Fast_Determination_of_Transient_Short-Circuit_Current_of_PM_Synchronous_Machines_Via_Magnetostatic_Flux_Maps_compressed.pdf

non disponibili

Tipologia: 2a Post-print versione editoriale / Version of Record
Licenza: Non Pubblico - Accesso privato/ristretto
Dimensione 821.96 kB
Formato Adobe PDF
821.96 kB Adobe PDF   Visualizza/Apri   Richiedi una copia
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11583/2978041