Backgrounds: The present study was designed to define: (1) which are the less predictable OTM with Invisalign aligners when the treatment plan is designed by expert operators, (2) if the presence and shape of attachments influence the predictability of OTM and (3) if patients' demographics influence OTM predictability. The sample comprises 79 prospectively recruited patients (mean age 30.8 years; SD 12.0; 23 M, 56 F), treated by expert operators with an average of 27 aligners (SD 15) in the maxillary arch and 25 aligners (SD 11) in the mandibular arch. Post-treatment digital models and final virtual treatment plan models were exported from ClinCheck((R)) software as STL files and subsequently imported into Geomagic Qualify ((R))software, to compare final teeth positions. The differences were calculated and tested for statistical significance for each tooth in the mesial-distal, vestibular-lingual and occlusal-gingival directions, as well as for angulation, inclination and rotation. In addition, the statistical significance of categorical variables was tested.Results: The lack of correction was significant for all movements and in all group of teeth (P < 0.01) except for the rotation of maxillary first molar. The prescribed OTM, the group of teeth and movement, the frequency of aligner change and the use of attachment influence the outcome. The greatest discrepancies in predicted and achieved tooth position were found for angular movements and rotation of teeth characterized by round-shaped crowns, for a ratio of approximately 0.4 degrees per 1 degrees prescribed. Optimized attachments for upper canines and lower premolar rotation seem not working properly. Second molar movements are mostly unexpressed. Furthermore, changing the aligner every 14 days will reduce the lack of correction of the 12% with respect to 7 days aligner change.Conclusions: Predictability of orthodontic movement with aligners still has limitations related to the biomechanics of the system: the shape of some attachments and the characteristics of aligner material need to be redefined. However, the results of this study allow to properly design the virtual treatment plan, revealing how much overcorrection is needed and which attachments are most effective.

Predictability of orthodontic tooth movement with aligners: effect of treatment design / Castroflorio, Tommaso; Sedran, Ambra; Parrini, Simone; Garino, Francesco; Reverdito, Matteo; Capuozzo, Riccardo; Mutinelli, Sabrina; Grybauskas, Simonas; Vaitiekūnas, Mantas; Deregibus, Andrea. - In: PROGRESS IN ORTHODONTICS. - ISSN 2196-1042. - 24:1(2023), p. 2. [10.1186/s40510-022-00453-0]

Predictability of orthodontic tooth movement with aligners: effect of treatment design

Sedran, Ambra;
2023

Abstract

Backgrounds: The present study was designed to define: (1) which are the less predictable OTM with Invisalign aligners when the treatment plan is designed by expert operators, (2) if the presence and shape of attachments influence the predictability of OTM and (3) if patients' demographics influence OTM predictability. The sample comprises 79 prospectively recruited patients (mean age 30.8 years; SD 12.0; 23 M, 56 F), treated by expert operators with an average of 27 aligners (SD 15) in the maxillary arch and 25 aligners (SD 11) in the mandibular arch. Post-treatment digital models and final virtual treatment plan models were exported from ClinCheck((R)) software as STL files and subsequently imported into Geomagic Qualify ((R))software, to compare final teeth positions. The differences were calculated and tested for statistical significance for each tooth in the mesial-distal, vestibular-lingual and occlusal-gingival directions, as well as for angulation, inclination and rotation. In addition, the statistical significance of categorical variables was tested.Results: The lack of correction was significant for all movements and in all group of teeth (P < 0.01) except for the rotation of maxillary first molar. The prescribed OTM, the group of teeth and movement, the frequency of aligner change and the use of attachment influence the outcome. The greatest discrepancies in predicted and achieved tooth position were found for angular movements and rotation of teeth characterized by round-shaped crowns, for a ratio of approximately 0.4 degrees per 1 degrees prescribed. Optimized attachments for upper canines and lower premolar rotation seem not working properly. Second molar movements are mostly unexpressed. Furthermore, changing the aligner every 14 days will reduce the lack of correction of the 12% with respect to 7 days aligner change.Conclusions: Predictability of orthodontic movement with aligners still has limitations related to the biomechanics of the system: the shape of some attachments and the characteristics of aligner material need to be redefined. However, the results of this study allow to properly design the virtual treatment plan, revealing how much overcorrection is needed and which attachments are most effective.
File in questo prodotto:
File Dimensione Formato  
s40510-022-00453-0.pdf

accesso aperto

Tipologia: 2a Post-print versione editoriale / Version of Record
Licenza: Creative commons
Dimensione 1.17 MB
Formato Adobe PDF
1.17 MB Adobe PDF Visualizza/Apri
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11583/2976551