The development of personalized healthcare is rapidly growing thanks to the support of low-power electronics, advanced fabrication processes and secured data transmission protocols. Long-acting drug delivery systems able to sustain the release of therapeutics in a controllable manner can provide several advantages in the treatment of chronic diseases. Various systems under development control drug release from an implantable reservoir via concentration driven diffusion through nanofluidic membranes. Given the high drug concentration in the reservoir, an inward osmotic fluid transport occurs across the membrane, which counters the outward diffusion of drugs. The resulting osmotic pressure buildup may be sufficient to cause the failure of implants with associated risks to patients. Confidently assessing the osmotic pressure buildup requires testing in vivo. Here, using metal and polymer AM (additive manufacturing) processes, we designed and developed implantable drug reservoirs with embedded strain sensors to directly measure the osmotic pressure in drug delivery implants in vitro and in vivo.

Integration of Strain Sensors on Additively Manufactured Implantable Devices / Graziano, Marta; DE PASQUALE, Giorgio. - In: JOURNAL OF MATERIALS SCIENCE AND ENGINEERING. B. - ISSN 2161-6221. - ELETTRONICO. - 11:(2021), pp. 133-137. [10.17265/2161-6221/2021.10-12.001]

Integration of Strain Sensors on Additively Manufactured Implantable Devices

Giorgio De Pasquale
2021

Abstract

The development of personalized healthcare is rapidly growing thanks to the support of low-power electronics, advanced fabrication processes and secured data transmission protocols. Long-acting drug delivery systems able to sustain the release of therapeutics in a controllable manner can provide several advantages in the treatment of chronic diseases. Various systems under development control drug release from an implantable reservoir via concentration driven diffusion through nanofluidic membranes. Given the high drug concentration in the reservoir, an inward osmotic fluid transport occurs across the membrane, which counters the outward diffusion of drugs. The resulting osmotic pressure buildup may be sufficient to cause the failure of implants with associated risks to patients. Confidently assessing the osmotic pressure buildup requires testing in vivo. Here, using metal and polymer AM (additive manufacturing) processes, we designed and developed implantable drug reservoirs with embedded strain sensors to directly measure the osmotic pressure in drug delivery implants in vitro and in vivo.
File in questo prodotto:
File Dimensione Formato  
2022 Graziano - De Pasquale (Journal of Materials Science and Engineering B).pdf

accesso aperto

Descrizione: Paper
Tipologia: 2a Post-print versione editoriale / Version of Record
Licenza: Creative commons
Dimensione 843.12 kB
Formato Adobe PDF
843.12 kB Adobe PDF Visualizza/Apri
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11583/2974784