Access to complex stenotic pulmonary arteries can be challenging due to their anatomy or secondary to prior multiple surgeries and interventions. Two techniques have been previously described to address this issue: the telescopic catheter-in-long sheath parallel to a stiff guidewire technique and the use of a microcatheter in a telescopic scope. We integrated and modified these techniques creating a super telescopic system with a SuperCross (R) microcatheter-in-catheter-in-long sheath, parallel to a contralateral stiff guidewire to access a previously repaired and stented left pulmonary artery. The stiff wire support and the 90 degrees flexiblity of the Supercross (R) microcatheter assembled coaxial to the diagnostic catheter and the long sheath contributed to the successful ballooning and stenting-in-stent of the pulmonary artery.
Super telescopic catheter system parallel to a contralateral stiff guide wire to cross extremely complex pulmonary arteries / Piccinelli, Enrico; Bautista-Rodriguez, Carles; Fraisse, Alain. - In: CARDIOLOGY IN THE YOUNG. - ISSN 1047-9511. - (2022), pp. 1-3. [10.1017/S1047951122000464]
Super telescopic catheter system parallel to a contralateral stiff guide wire to cross extremely complex pulmonary arteries
Piccinelli, Enrico;
2022
Abstract
Access to complex stenotic pulmonary arteries can be challenging due to their anatomy or secondary to prior multiple surgeries and interventions. Two techniques have been previously described to address this issue: the telescopic catheter-in-long sheath parallel to a stiff guidewire technique and the use of a microcatheter in a telescopic scope. We integrated and modified these techniques creating a super telescopic system with a SuperCross (R) microcatheter-in-catheter-in-long sheath, parallel to a contralateral stiff guidewire to access a previously repaired and stented left pulmonary artery. The stiff wire support and the 90 degrees flexiblity of the Supercross (R) microcatheter assembled coaxial to the diagnostic catheter and the long sheath contributed to the successful ballooning and stenting-in-stent of the pulmonary artery.File | Dimensione | Formato | |
---|---|---|---|
2022 - Super-telescopic catheter system parallel to a contralateral stiff guide wire to cross extremely complex pulmonary arteries.pdf
accesso aperto
Tipologia:
2a Post-print versione editoriale / Version of Record
Licenza:
PUBBLICO - Tutti i diritti riservati
Dimensione
878.87 kB
Formato
Adobe PDF
|
878.87 kB | Adobe PDF | Visualizza/Apri |
Pubblicazioni consigliate
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.
https://hdl.handle.net/11583/2970589