Background: Balloon dilation and stenting of the atrial septum are techniques used to unload left heart cavities in acute or end-stage heart failure in children. However, they carry significant risks such as tamponade or device embolization.Case Presentation: We report the first case of a child with an end-stage mitochondrial cardiomyopathy on a venoarterial extracorporeal membrane oxygenator as a bridge to heart transplant where an atrial flow regulator device has been implanted.Conclusions: This case illustrates the feasibility and safety of atrial flow regulator implantation in this setting. This procedure allowed to wean inotropic support while awaiting heart transplantation.

Implantation of an Atrial Flow Regulator in a Child on Venoarterial Extracorporeal Membrane Oxygenator as a Bridge to Heart Transplant: A Case Report / Piccinelli, Enrico; Castro-Verdes, Mireya Beatriz; Fraisse, Alain; Bautista-Rodriguez, Carles. - In: JOURNAL OF CARDIAC FAILURE. - ISSN 1532-8414. - ELETTRONICO. - 27:3(2021), pp. 364-367. [10.1016/j.cardfail.2020.11.006]

Implantation of an Atrial Flow Regulator in a Child on Venoarterial Extracorporeal Membrane Oxygenator as a Bridge to Heart Transplant: A Case Report

Piccinelli, Enrico;
2021

Abstract

Background: Balloon dilation and stenting of the atrial septum are techniques used to unload left heart cavities in acute or end-stage heart failure in children. However, they carry significant risks such as tamponade or device embolization.Case Presentation: We report the first case of a child with an end-stage mitochondrial cardiomyopathy on a venoarterial extracorporeal membrane oxygenator as a bridge to heart transplant where an atrial flow regulator device has been implanted.Conclusions: This case illustrates the feasibility and safety of atrial flow regulator implantation in this setting. This procedure allowed to wean inotropic support while awaiting heart transplantation.
File in questo prodotto:
File Dimensione Formato  
2020 - Implantation of an Atrial Flow Regulator in a Child on Venoarterial Extracorporeal Membrane Oxygenator as a Bridge to Heart Transplant A Case Report.pdf

non disponibili

Tipologia: 2a Post-print versione editoriale / Version of Record
Licenza: Non Pubblico - Accesso privato/ristretto
Dimensione 830.62 kB
Formato Adobe PDF
830.62 kB Adobe PDF   Visualizza/Apri   Richiedi una copia
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11583/2970582