Background: Balloon dilation and stenting of the atrial septum are techniques used to unload left heart cavities in acute or end-stage heart failure in children. However, they carry significant risks such as tamponade or device embolization.Case Presentation: We report the first case of a child with an end-stage mitochondrial cardiomyopathy on a venoarterial extracorporeal membrane oxygenator as a bridge to heart transplant where an atrial flow regulator device has been implanted.Conclusions: This case illustrates the feasibility and safety of atrial flow regulator implantation in this setting. This procedure allowed to wean inotropic support while awaiting heart transplantation.
Implantation of an Atrial Flow Regulator in a Child on Venoarterial Extracorporeal Membrane Oxygenator as a Bridge to Heart Transplant: A Case Report / Piccinelli, Enrico; Castro-Verdes, Mireya Beatriz; Fraisse, Alain; Bautista-Rodriguez, Carles. - In: JOURNAL OF CARDIAC FAILURE. - ISSN 1532-8414. - ELETTRONICO. - 27:3(2021), pp. 364-367. [10.1016/j.cardfail.2020.11.006]
Implantation of an Atrial Flow Regulator in a Child on Venoarterial Extracorporeal Membrane Oxygenator as a Bridge to Heart Transplant: A Case Report
Piccinelli, Enrico;
2021
Abstract
Background: Balloon dilation and stenting of the atrial septum are techniques used to unload left heart cavities in acute or end-stage heart failure in children. However, they carry significant risks such as tamponade or device embolization.Case Presentation: We report the first case of a child with an end-stage mitochondrial cardiomyopathy on a venoarterial extracorporeal membrane oxygenator as a bridge to heart transplant where an atrial flow regulator device has been implanted.Conclusions: This case illustrates the feasibility and safety of atrial flow regulator implantation in this setting. This procedure allowed to wean inotropic support while awaiting heart transplantation.File | Dimensione | Formato | |
---|---|---|---|
2020 - Implantation of an Atrial Flow Regulator in a Child on Venoarterial Extracorporeal Membrane Oxygenator as a Bridge to Heart Transplant A Case Report.pdf
non disponibili
Tipologia:
2a Post-print versione editoriale / Version of Record
Licenza:
Non Pubblico - Accesso privato/ristretto
Dimensione
830.62 kB
Formato
Adobe PDF
|
830.62 kB | Adobe PDF | Visualizza/Apri Richiedi una copia |
Pubblicazioni consigliate
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.
https://hdl.handle.net/11583/2970582