European energy policy encourages the railway stakeholders to adopt technological solutions to reduce the railway transport emissions by 50% within 2030. To this aim, the dynamic braking combined with the adoption of reversible substations is one of the most promising solutions. To deepen the knowledge of this new technology in its practical application, this paper presents the results of a measurement campaign that has been conducted on-board of a train operating on the metro line that serves the city of Madrid, where a reversible substation was installed. The installed measurement system allows the accurate measurements of the energy flows and the losses. The monitoring has been performed both when the substation acts as reversible and when operates in a traditional way. The comparison could be used to quantify the impact of these technologies in a real application, providing information on energy saving in the different operating conditions and presenting a methodology to quantify them.

Impact of a reversible substation on energy recovery experienced on-board a train / Cascetta, F.; Cipolletta, G.; Delle Femine, A.; Quintana Fernandez, J.; Gallo, D.; Giordano, D.; Signorino, D.. - In: MEASUREMENT. - ISSN 0263-2241. - ELETTRONICO. - 183:(2021), p. 109793. [10.1016/j.measurement.2021.109793]

Impact of a reversible substation on energy recovery experienced on-board a train

Giordano D.;Signorino D.
2021

Abstract

European energy policy encourages the railway stakeholders to adopt technological solutions to reduce the railway transport emissions by 50% within 2030. To this aim, the dynamic braking combined with the adoption of reversible substations is one of the most promising solutions. To deepen the knowledge of this new technology in its practical application, this paper presents the results of a measurement campaign that has been conducted on-board of a train operating on the metro line that serves the city of Madrid, where a reversible substation was installed. The installed measurement system allows the accurate measurements of the energy flows and the losses. The monitoring has been performed both when the substation acts as reversible and when operates in a traditional way. The comparison could be used to quantify the impact of these technologies in a real application, providing information on energy saving in the different operating conditions and presenting a methodology to quantify them.
File in questo prodotto:
File Dimensione Formato  
Signorino-Impact-of-a-reversible.pdf

non disponibili

Tipologia: 2a Post-print versione editoriale / Version of Record
Licenza: Non Pubblico - Accesso privato/ristretto
Dimensione 3.46 MB
Formato Adobe PDF
3.46 MB Adobe PDF   Visualizza/Apri   Richiedi una copia
Measurement_reviewed_Finale19.pdf

Open Access dal 27/06/2023

Tipologia: 2. Post-print / Author's Accepted Manuscript
Licenza: Creative commons
Dimensione 1.55 MB
Formato Adobe PDF
1.55 MB Adobe PDF Visualizza/Apri
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11583/2969112