The compliance with the indoor environmental quality (IEQ) requirements should be considered when designing retrofit actions for the refurbishment of existing buildings. The research is aimed to reduce the imbalance between the visual and thermal domains through the improvement of different design parameters in compliance with the nearly zero-energy building (nZEB) requirements. The article proposes a novel approach based on the integrated lighting, thermal, and energy dynamic simulation, to evaluate the overall building performance according to energy saving, cost effectiveness, and IEQ multi-criteria. Different energy efficiency actions, in terms of insulation materials, glazing solutions, and control strategies of the solar shading devices, have been applied to an existing office building-type. The analysis shows the possibility to design the refurbishment of an existing building into a nZEB while ensuring visual and thermal comfort. However, the not negligible costs lead to an incompliance with the cost-effectiveness requirements.
On the improvement of indoor environmental quality, energy performance and costs for a commercial nearly zero-energy building / DE LUCA, Giovanna; Ballarini, Ilaria; Paragamyan, Argun; Pellegrino, Anna; Corrado, Vincenzo. - In: SCIENCE AND TECHNOLOGY FOR THE BUILT ENVIRONMENT. - ISSN 2374-474X. - ELETTRONICO. - 27:8(2021), pp. 1056-1074. [10.1080/23744731.2021.1940275]
On the improvement of indoor environmental quality, energy performance and costs for a commercial nearly zero-energy building
DE LUCA, GIOVANNA;BALLARINI , ILARIA;PARAGAMYAN, ARGUN;PELLEGRINO, ANNA;CORRADO, VINCENZO
2021
Abstract
The compliance with the indoor environmental quality (IEQ) requirements should be considered when designing retrofit actions for the refurbishment of existing buildings. The research is aimed to reduce the imbalance between the visual and thermal domains through the improvement of different design parameters in compliance with the nearly zero-energy building (nZEB) requirements. The article proposes a novel approach based on the integrated lighting, thermal, and energy dynamic simulation, to evaluate the overall building performance according to energy saving, cost effectiveness, and IEQ multi-criteria. Different energy efficiency actions, in terms of insulation materials, glazing solutions, and control strategies of the solar shading devices, have been applied to an existing office building-type. The analysis shows the possibility to design the refurbishment of an existing building into a nZEB while ensuring visual and thermal comfort. However, the not negligible costs lead to an incompliance with the cost-effectiveness requirements.File | Dimensione | Formato | |
---|---|---|---|
STBE_De Luca et al._2021.pdf
non disponibili
Descrizione: Articolo principale
Tipologia:
2a Post-print versione editoriale / Version of Record
Licenza:
Non Pubblico - Accesso privato/ristretto
Dimensione
3.43 MB
Formato
Adobe PDF
|
3.43 MB | Adobe PDF | Visualizza/Apri Richiedi una copia |
Pubblicazioni consigliate
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.
https://hdl.handle.net/11583/2933412