Microwave imaging is an imaging technique that can be applied to human brain tissues with the potentiality to improve diagnostic ability and to enable earlier diagnosis in the case of trauma and stroke patients [1] . The current most used medical imaging modalities are magnetic resonance imaging (MRI) and computerized tomography (CT) that are assessed and reliable diagnostic tools, however they can be time consuming, costly, not available for bedside monitoring, and harmful due to ionizing radiations (in the CT case only). Hence, microwave imaging can be considered as a complementary diagnostic imaging technique, in particular for bedside and ambulance human head monitoring (see e.g. the systems described in [2] , [3] ).

Experimental Imaging Issues of a 3-D Microwave Brain Scanner / Tobon Vasquez, J. A.; Rodriguez-Duarte, D. O.; Scapaticci, R.; Turvani, G.; Bellizzi, G.; Joachimowicz, N.; Duchêne, B.; Casu, M. R.; Crocco, L.; Vipiana, F.. - ELETTRONICO. - (2021). (Intervento presentato al convegno ICEAA-IEEE APWC-USNC URSI RSM 2021 tenutosi a Honolulu, HI, USA nel 9-13 Aug. 2021) [10.1109/ICEAA52647.2021.9539824].

Experimental Imaging Issues of a 3-D Microwave Brain Scanner

J. A. Tobon Vasquez;D. O. Rodriguez-Duarte;G. Turvani;M. R. Casu;F. Vipiana
2021

Abstract

Microwave imaging is an imaging technique that can be applied to human brain tissues with the potentiality to improve diagnostic ability and to enable earlier diagnosis in the case of trauma and stroke patients [1] . The current most used medical imaging modalities are magnetic resonance imaging (MRI) and computerized tomography (CT) that are assessed and reliable diagnostic tools, however they can be time consuming, costly, not available for bedside monitoring, and harmful due to ionizing radiations (in the CT case only). Hence, microwave imaging can be considered as a complementary diagnostic imaging technique, in particular for bedside and ambulance human head monitoring (see e.g. the systems described in [2] , [3] ).
File in questo prodotto:
File Dimensione Formato  
408_Paper_2021057585.pdf

accesso aperto

Descrizione: Articolo principale
Tipologia: 2. Post-print / Author's Accepted Manuscript
Licenza: PUBBLICO - Tutti i diritti riservati
Dimensione 114.9 kB
Formato Adobe PDF
114.9 kB Adobe PDF Visualizza/Apri
Experimental_Imaging_Issues_of_a_3-D_Microwave_Brain_Scanner.pdf

non disponibili

Descrizione: Published file
Tipologia: 2a Post-print versione editoriale / Version of Record
Licenza: Non Pubblico - Accesso privato/ristretto
Dimensione 1.24 MB
Formato Adobe PDF
1.24 MB Adobe PDF   Visualizza/Apri   Richiedi una copia
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11583/2920756