The ITER Central Solenoid (CS) will be manufactured by assembling a stack of six modules, which are under fabrication by the US ITER organization and its subcontractors. The tests of the first CS Module have been performed at the premises of the General Atomics (GA) facility in Poway (US), in order to check compliance to the ITER requirements. Among other tests, the magnet was submitted to exponential dumps of the transport current from different initial values (10, 15, 20, 22.5, 25, 35, 40 kA) down to 0 kA. These tests are aimed at conducting DC breaker commissioning of the test facility and were used to measure the AC losses in the coil during electrodynamic transients. This paper presents the results of these measurements, along with a comparison with analytical computations of the losses in the magnet.

AC Losses in the First ITER CS Module Tests: Experimental Results and Comparison to Analytical Models / Breschi, M.; Cavallucci, L.; Ribani, P. L.; Bonifetto, R.; Zappatore, A.; Zanino, R.; Gauthier, F.; Bauer, P.; Martovetsky, N.. - In: IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY. - ISSN 1051-8223. - ELETTRONICO. - 31:5(2021), pp. 1-5. [10.1109/TASC.2021.3061950]

AC Losses in the First ITER CS Module Tests: Experimental Results and Comparison to Analytical Models

Bonifetto R.;Zappatore A.;Zanino R.;
2021

Abstract

The ITER Central Solenoid (CS) will be manufactured by assembling a stack of six modules, which are under fabrication by the US ITER organization and its subcontractors. The tests of the first CS Module have been performed at the premises of the General Atomics (GA) facility in Poway (US), in order to check compliance to the ITER requirements. Among other tests, the magnet was submitted to exponential dumps of the transport current from different initial values (10, 15, 20, 22.5, 25, 35, 40 kA) down to 0 kA. These tests are aimed at conducting DC breaker commissioning of the test facility and were used to measure the AC losses in the coil during electrodynamic transients. This paper presents the results of these measurements, along with a comparison with analytical computations of the losses in the magnet.
File in questo prodotto:
File Dimensione Formato  
AC_Losses_in_the_First_ITER_CS_Module_Tests_Experimental_Results_and_Comparison_to_Analytical_Models.pdf

non disponibili

Tipologia: 2a Post-print versione editoriale / Version of Record
Licenza: Non Pubblico - Accesso privato/ristretto
Dimensione 926.18 kB
Formato Adobe PDF
926.18 kB Adobe PDF   Visualizza/Apri   Richiedi una copia
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11583/2905538