The ITER Central Solenoid (CS) modules are under fabrication by the US ITER organization and its subcontractors. US ITER will supply seven modules to the ITER Organization (IO), six of which will be assembled in a stack that forms the ITER Central Solenoid, the last one being spare. The first module, namely CSM 1 was manufactured by General Atomics (GA) and went through Factory Acceptance Tests (FAT) including high voltage testing, Paschen testing and then cold test at 4.5 K and up to 40.0 kA in order to demonstrate compliance with coil performance requirements. The paper focuses on the results of the first CS Module thermal hydraulic characterization without current (and field). Pressure drops, transit time, and thermal coupling between pancakes are presented. Analysis results and tests are also compared.

Thermal Hydraulic Behavior of the First ITER CS Module / Gauthier, F.; Schild, T.; Martovetsky, N. N.; Khumthong, K.; Schaubel, K. M.; Sheeron, J.; Langhorn, A. R.; Bonifetto, R.; Zanino, R.; Zappatore, A.. - In: IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY. - ISSN 1051-8223. - ELETTRONICO. - 31:5(2021), pp. 1-5. [10.1109/TASC.2021.3053505]

Thermal Hydraulic Behavior of the First ITER CS Module

Bonifetto R.;Zanino R.;Zappatore A.
2021

Abstract

The ITER Central Solenoid (CS) modules are under fabrication by the US ITER organization and its subcontractors. US ITER will supply seven modules to the ITER Organization (IO), six of which will be assembled in a stack that forms the ITER Central Solenoid, the last one being spare. The first module, namely CSM 1 was manufactured by General Atomics (GA) and went through Factory Acceptance Tests (FAT) including high voltage testing, Paschen testing and then cold test at 4.5 K and up to 40.0 kA in order to demonstrate compliance with coil performance requirements. The paper focuses on the results of the first CS Module thermal hydraulic characterization without current (and field). Pressure drops, transit time, and thermal coupling between pancakes are presented. Analysis results and tests are also compared.
File in questo prodotto:
File Dimensione Formato  
Thermal_Hydraulic_Behavior_of_the_First_ITER_CS_Module.pdf

non disponibili

Tipologia: 2a Post-print versione editoriale / Version of Record
Licenza: Non Pubblico - Accesso privato/ristretto
Dimensione 2.69 MB
Formato Adobe PDF
2.69 MB Adobe PDF   Visualizza/Apri   Richiedi una copia
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11583/2905536