This work studies the technical and economic feasibility of the introduction of a SOFC-based cogeneration system to supply non-residential buildings with electricity and heat. The techno-economic evaluation is performed for the hotel and hospital sectors, by introducing real hourly load profiles (electrical and thermal) for the buildings. The analysis considers different countries in terms of energy intensity (and load profiles), cost of energy and regulations/incentives. Results are achieved by comparing the SOFC scenario with a benchmark one where electricity is supplied by the grid and heat by a natural gas fed boiler and evaluating the relative payback time between the two solutions. The analysis showed that, despite the current high investment cost of the SOFC system, in countries such as Germany, Italy and UK (where electricity prices are among the highest in Europe), the option is yet advisable if supported by effective subsidies (already existing for cogeneration systems), and it could offer a competitive alternative to traditional systems, especially in the hospital sector, where the relative payback time is achieved in the 10th year for UK, and in the 14th year for Germany and Italy. A cost reduction scenario has also been analyzed: results show that the SOFC is the best option in most of the locations, both economically and in terms of environmental impact (pollutants emissions reduction).

Installation of fuel cell-based cogeneration systems in the commercial and retail sector: Assessment in the framework of the {COMSOS} project / Accurso, F.; Gandiglio, M.; Santarelli, M.; Buunk, J; Hakala, T.; Kiviaho, J.; Modena, S.; Mã¼nch, M.; Varkaraki, E.. - In: ENERGY CONVERSION AND MANAGEMENT. - ISSN 0196-8904. - 239:(2021), p. 114202. [10.1016/j.enconman.2021.114202]

Installation of fuel cell-based cogeneration systems in the commercial and retail sector: Assessment in the framework of the {COMSOS} project

M. Gandiglio;M. Santarelli;
2021

Abstract

This work studies the technical and economic feasibility of the introduction of a SOFC-based cogeneration system to supply non-residential buildings with electricity and heat. The techno-economic evaluation is performed for the hotel and hospital sectors, by introducing real hourly load profiles (electrical and thermal) for the buildings. The analysis considers different countries in terms of energy intensity (and load profiles), cost of energy and regulations/incentives. Results are achieved by comparing the SOFC scenario with a benchmark one where electricity is supplied by the grid and heat by a natural gas fed boiler and evaluating the relative payback time between the two solutions. The analysis showed that, despite the current high investment cost of the SOFC system, in countries such as Germany, Italy and UK (where electricity prices are among the highest in Europe), the option is yet advisable if supported by effective subsidies (already existing for cogeneration systems), and it could offer a competitive alternative to traditional systems, especially in the hospital sector, where the relative payback time is achieved in the 10th year for UK, and in the 14th year for Germany and Italy. A cost reduction scenario has also been analyzed: results show that the SOFC is the best option in most of the locations, both economically and in terms of environmental impact (pollutants emissions reduction).
File in questo prodotto:
File Dimensione Formato  
1-s2.0-S0196890421003782-main.pdf

accesso aperto

Tipologia: 2a Post-print versione editoriale / Version of Record
Licenza: Creative commons
Dimensione 3.38 MB
Formato Adobe PDF
3.38 MB Adobe PDF Visualizza/Apri
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11583/2899252