A novel integrated renewable-based energy system for production of synthetic diesel is proposed and simulated in this study. This system merges solid oxide electrolyser (SOE), entrained gasification (EG) and Fischer-Tropsch (FT) technologies. Two case scenarios are considered here. In the first case, the electrolyser unite produce syngas through co-electrolysis of steam and carbon dioxide, while in the second case only steam is electrolyzed. The effects of SOEC and EG operating pressure and temperatures on the system performance in each case are investigated and compared. It is shown that the operating condition of electrolyser subsystem has a more considerable effect on the performance of the integrated system as compared to the gasification subsystem. Also waste heat recovery results in about 43 and 2 percentage point increase in energy and exergy efficiency, respectively. It is also shown that internal recovering of oxygen has the best effect on the system performance.

Integration of solid oxide electrolyser, entrained gasification, and Fischer-Tropsch process for synthetic diesel production: Thermodynamic analysis / Samavati, M.; Martin, A.; Nemanova, V.; Santarelli, M.. - In: INTERNATIONAL JOURNAL OF HYDROGEN ENERGY. - ISSN 0360-3199. - 43:10(2018), pp. 4785-4803. [10.1016/j.ijhydene.2018.01.138]

Integration of solid oxide electrolyser, entrained gasification, and Fischer-Tropsch process for synthetic diesel production: Thermodynamic analysis

Samavati M.;Santarelli M.
2018

Abstract

A novel integrated renewable-based energy system for production of synthetic diesel is proposed and simulated in this study. This system merges solid oxide electrolyser (SOE), entrained gasification (EG) and Fischer-Tropsch (FT) technologies. Two case scenarios are considered here. In the first case, the electrolyser unite produce syngas through co-electrolysis of steam and carbon dioxide, while in the second case only steam is electrolyzed. The effects of SOEC and EG operating pressure and temperatures on the system performance in each case are investigated and compared. It is shown that the operating condition of electrolyser subsystem has a more considerable effect on the performance of the integrated system as compared to the gasification subsystem. Also waste heat recovery results in about 43 and 2 percentage point increase in energy and exergy efficiency, respectively. It is also shown that internal recovering of oxygen has the best effect on the system performance.
File in questo prodotto:
File Dimensione Formato  
1-s2.0-S0360319918302544-main.pdf

non disponibili

Tipologia: 2a Post-print versione editoriale / Version of Record
Licenza: Non Pubblico - Accesso privato/ristretto
Dimensione 3.18 MB
Formato Adobe PDF
3.18 MB Adobe PDF   Visualizza/Apri   Richiedi una copia
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11583/2866106