Purpose: To compare the incidence of distal emboli occurring during percutaneous transluminal angioplasty (PTA) and primary stent on the superficial femoral artery (SFA) Methods: A total of 50 consecutive patients were entered in a prospective, randomized trial. Inclusion criteria were the presence of symptomatic limb ischemia due to stenosis or occlusion of the SFA. An embolic protection device was placed in the popliteal artery. The patients were then randomly assigned to undergo primary stent implantation or PTA. The filters were retrieved and sent for histologic examination. Results: Stenting in the SFA produced more emboli (1.44 mm3) than PTA (0.772 mm3), P =.031. Reanalyzing the patients according to actual treatment performed, volume of debris in the stent group was 1.271 mm3 and in the PTA group was 0.191 mm3, P =.00087. Conclusion: Volume of embolized material during endovascular interventions in the SFA-above-knee popliteal artery is higher when a stent is used. © The Author(s) 2012.
Comparison of Embolic Load in Femoropopliteal Interventions: Percutaneous Transluminal Angioplasty Versus Stenting / Brancaccio, G.; Lombardi, R.; Stefanini, T.; Torri, P.; Russo, D.; Gorji, N.; Cappelletti, D.; Celoria, G. M.. - In: VASCULAR AND ENDOVASCULAR SURGERY. - ISSN 1538-5744. - STAMPA. - 46:3(2012), pp. 229-235. [10.1177/1538574411422276]
Comparison of Embolic Load in Femoropopliteal Interventions: Percutaneous Transluminal Angioplasty Versus Stenting
Cappelletti D.;
2012
Abstract
Purpose: To compare the incidence of distal emboli occurring during percutaneous transluminal angioplasty (PTA) and primary stent on the superficial femoral artery (SFA) Methods: A total of 50 consecutive patients were entered in a prospective, randomized trial. Inclusion criteria were the presence of symptomatic limb ischemia due to stenosis or occlusion of the SFA. An embolic protection device was placed in the popliteal artery. The patients were then randomly assigned to undergo primary stent implantation or PTA. The filters were retrieved and sent for histologic examination. Results: Stenting in the SFA produced more emboli (1.44 mm3) than PTA (0.772 mm3), P =.031. Reanalyzing the patients according to actual treatment performed, volume of debris in the stent group was 1.271 mm3 and in the PTA group was 0.191 mm3, P =.00087. Conclusion: Volume of embolized material during endovascular interventions in the SFA-above-knee popliteal artery is higher when a stent is used. © The Author(s) 2012.File | Dimensione | Formato | |
---|---|---|---|
1538574411422276.pdf
accesso riservato
Descrizione: Articolo principale
Tipologia:
2a Post-print versione editoriale / Version of Record
Licenza:
Non Pubblico - Accesso privato/ristretto
Dimensione
128.39 kB
Formato
Adobe PDF
|
128.39 kB | Adobe PDF | Visualizza/Apri Richiedi una copia |
Pubblicazioni consigliate
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.
https://hdl.handle.net/11583/2857188