This work deals with the improvement of the room acoustic quality of two medium sized meeting rooms through the investigation of the optimal placement of absorption and diffusive panels on the walls and ceiling. Acoustic measurements have been carried out in the existing untreated rooms with ODEON 13 room acoustics measurement and prediction software, and the Adobe Audition plugins Aurora. Simulations of different combinations of sound absorption and diffusion treatments have been carried out with the updated version of the software, ODEON 15. The panels were positioned in the meeting rooms following the guidelines of the DIN 18041 standard and the scientific literature. The results advise the application of absorptive materials on the ceiling or around the borders, creating a reflective middle area, and on the upper part of one the lateral walls, including the rear wall. Configurations with diffusers do not generally bring significant improvements. The Speech Transmission Index (STI) is a less sensitive parameter for the different acoustic scenarios, compared to Reverberation Time (T) and Clarity (C50). The research also outlined a design workflow, useful to successfully design meeting rooms and rooms for speech in general, which allows to determine the optimal number and location of acoustic panels and to minimize the costs.

Improved Room Acoustics Quality in Meeting Rooms: Investigation on the Optimal Configurations of Sound-Absorptive and Sound-Diffusive Panels / Labia, Laura; Shtrepi, Louena; Astolfi, Arianna. - In: ACOUSTICS. - ISSN 2624-599X. - ELETTRONICO. - 2:3(2020), pp. 451-473. [10.3390/acoustics2030025]

Improved Room Acoustics Quality in Meeting Rooms: Investigation on the Optimal Configurations of Sound-Absorptive and Sound-Diffusive Panels

Shtrepi, Louena;Astolfi, Arianna
2020

Abstract

This work deals with the improvement of the room acoustic quality of two medium sized meeting rooms through the investigation of the optimal placement of absorption and diffusive panels on the walls and ceiling. Acoustic measurements have been carried out in the existing untreated rooms with ODEON 13 room acoustics measurement and prediction software, and the Adobe Audition plugins Aurora. Simulations of different combinations of sound absorption and diffusion treatments have been carried out with the updated version of the software, ODEON 15. The panels were positioned in the meeting rooms following the guidelines of the DIN 18041 standard and the scientific literature. The results advise the application of absorptive materials on the ceiling or around the borders, creating a reflective middle area, and on the upper part of one the lateral walls, including the rear wall. Configurations with diffusers do not generally bring significant improvements. The Speech Transmission Index (STI) is a less sensitive parameter for the different acoustic scenarios, compared to Reverberation Time (T) and Clarity (C50). The research also outlined a design workflow, useful to successfully design meeting rooms and rooms for speech in general, which allows to determine the optimal number and location of acoustic panels and to minimize the costs.
2020
File in questo prodotto:
File Dimensione Formato  
acoustics-02-00025-v2.pdf

accesso aperto

Descrizione: Articolo principale
Tipologia: 2a Post-print versione editoriale / Version of Record
Licenza: Creative commons
Dimensione 3.9 MB
Formato Adobe PDF
3.9 MB Adobe PDF Visualizza/Apri
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11583/2838507