Antenna-pointing techniques that rely on Earth's surface Doppler velocity measurements are expected to play a crucial role in enabling antenna mispointing corrections in spaceborne radar systems. Here, the impact of the EarthCARE cloud profiling radar (CPR) receiver saturation on the quality of the surface Doppler velocity measurements is discussed. The CPR linear receiver is expected to saturate always from surface echoes. Our results based on an I/Q simulation framework show that for the EarthCARE radar configuration: 1) biases introduced by saturation will be negligible; 2) the standard deviation of the velocity estimates will increase by 30-50% when moving from unsaturated to completely saturated surface return for a corresponding pulse repetition frequency in the range between 6.1 and 7.5 kHz. As a consequence longer integration times will be necessary to achieve the same accuracy in presence of complete saturation.
Impact of receiver saturation on surface doppler velocity measurements from the EarthCARE cloud profiling radar / Battaglia, A.; Kollias, P.. - In: IEEE TRANSACTIONS ON GEOSCIENCE AND REMOTE SENSING. - ISSN 1558-0644. - 53:3(2015), pp. 1205-1212. [10.1109/TGRS.2014.2335896]
Impact of receiver saturation on surface doppler velocity measurements from the EarthCARE cloud profiling radar
Battaglia A.;
2015
Abstract
Antenna-pointing techniques that rely on Earth's surface Doppler velocity measurements are expected to play a crucial role in enabling antenna mispointing corrections in spaceborne radar systems. Here, the impact of the EarthCARE cloud profiling radar (CPR) receiver saturation on the quality of the surface Doppler velocity measurements is discussed. The CPR linear receiver is expected to saturate always from surface echoes. Our results based on an I/Q simulation framework show that for the EarthCARE radar configuration: 1) biases introduced by saturation will be negligible; 2) the standard deviation of the velocity estimates will increase by 30-50% when moving from unsaturated to completely saturated surface return for a corresponding pulse repetition frequency in the range between 6.1 and 7.5 kHz. As a consequence longer integration times will be necessary to achieve the same accuracy in presence of complete saturation.File | Dimensione | Formato | |
---|---|---|---|
BattagliaKolliasIEEE2014.pdf
non disponibili
Tipologia:
2a Post-print versione editoriale / Version of Record
Licenza:
Non Pubblico - Accesso privato/ristretto
Dimensione
1.6 MB
Formato
Adobe PDF
|
1.6 MB | Adobe PDF | Visualizza/Apri Richiedi una copia |
Pubblicazioni consigliate
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.
https://hdl.handle.net/11583/2807136